摘要
通过对印度BALCO 4×135MW项目低加疏水泵汽蚀原因进行分析,提出了解决汽蚀办法,为同类型机组设计提供借鉴经验。
This paper focuses on the analysis of cavitations in drain pump of Low Pressure heater of Indian Balco 4×135MW Power Plant and demonstrates the treatment process of the same, which will provide the referential experience for designing of same grade unit.
出处
《山东电力高等专科学校学报》
2008年第1期44-46,共3页
Journal of Shandong Electric Power College
关键词
低加疏水泵
汽蚀
汽蚀余量
LPH (low pressure heater)
drain pump cavitation
NPSH (net positive suction head)