期刊文献+

基于Matlab的配电网接地故障仿真 被引量:5

The Matlab Si mulation of Distribution Network Grounded Fault
下载PDF
导出
摘要 介绍了配电网不同接地方式的特点,利用Matlab的电力系统仿真平台,搭建了10kV配电网的模型。针对单相接地问题进行了仿真比较,给出了较为准确的数值仿真解,指出了中性点经消弧线圈接地方式的作用。 The characteristics of different grounded methods of distribution network is firstly analyzed. Using Matlab electric system simulated platform, the 10 kV distribution network model is made. According to the simulated comparison of single-line grounded issues, the accurate simulated solution and the function of neutral indirectly grounded system are indicated.
出处 《电气应用》 北大核心 2008年第16期54-57,共4页 Electrotechnical Application
关键词 消弧线圈 配电网 仿真 MATLAB arc-suppression coil distribution network simulation Matlab
  • 相关文献

参考文献7

  • 1要换年 曹梅月.电力系统谐振接地[M].北京:中国电力出版社,2000..
  • 2[3]李光琦.电力系统暂态分析[M].西安:西安交通大学出版社,1994.
  • 3贺家李.电力系统继电保护原理[M].北京:水利电力出版社,1991.
  • 4[5]Huang S J,Hsieh C T.Hight-impedance Fault Detection Utilizing a Modet Wavelet Transform Approach[J].IEEE Transactions on Power Delivery,1999,14(4):1 401-1 407.
  • 5贾清泉,肖鹏,杨以涵,刘连光,宋家骅.小电流接地电网单相接地故障的小波选线方法[J].继电器,2001,29(3):5-8. 被引量:47
  • 6毛鹏,孙雅明,张兆宁,杜红卫.小波包在配电网单相接地故障选线中的应用[J].电网技术,2000,24(6):9-13. 被引量:112
  • 7[9]Oinis C,Michiel M,Francoise B.A New Tool for the Resonant Grounded Power Distribution System Relaying[J].IEEE Transactions on Power Delivery,1996,11(3):1 301-1 308.

二级参考文献9