摘要
分析了由于空冷凝汽器散热器脏污导致机组运行背压升高的原因,经对空冷凝汽器散热器彻底冲洗,使背压降低了8 kPa,有效提高了机组的运行的经济性和安全性。
This paper analyzes the cause of the operation backpressure rising of unit owing to the dirtied radiator of ACC, through flushing completely the radiator of ACC,the backpressure reduced 8 kPa in result to raise effectively the operation economic and safety of unit.
出处
《华北电力技术》
CAS
2008年第8期52-54,共3页
North China Electric Power