期刊文献+

基于平底孔反射体的双晶直探头测量模型 被引量:6

An ultrasonic measurement model to predict the response from flat bottom hole for dual crystal contact probe
原文传递
导出
摘要 双晶探头在无损检测领域有着重要的应用,因而有必要建立一个超声测量模型来深入了解这类换能器的特点.通过将一个基于传递矩阵的多高斯声束模型和一个基尔霍夫近似方法获得的散射模型有效结合,建立了一个完整的纵波双晶直探头测量模型,用于预测平底孔缺陷体的回波信号.对比分析了平底孔反射回波信号的模型计算结果与实验测量结果,验证了该测量模型的准确性. Dual crystal contact probes play an important role in many practical ultrasonic inspections,so it is essential to develop an ultrasonic measurement model in order to get a thorough understanding of the characteristics of this kind of transducers.By combining the multi-Gaussian beam model and the Kirchhoff approximation scattering model,a complete ultrasonic measurement model is provided to predict testing signals of a flat bottom hole for a dual crystal focused direct contact probe.By comparing with experimental results,the accuracy of predicted signals using this model has been verified.
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2008年第8期5049-5055,共7页 Acta Physica Sinica
基金 国家自然科学基金(批准号:50775054,10774158) 科学技术部国际合作计划(批准号:2007DFR70070)资助的课题~~
关键词 超声测量模型 双晶直探头 多高斯声束模型 ultrasonic measurement model,dual crystal contact probe,multi-Gaussian beam model
  • 相关文献

参考文献15

  • 1Thompson R B 2002 Review of Progress in QNDE (Vol. 21) (New York: AIP) pp1917-1924
  • 2Bostrom A, Bovik P 2003 Int. J. Solids Struct. 40 3493
  • 3Kim H J, Song S J, Schmerr L W 2006 Ultrasonics 44 969
  • 4Wang Y H, Guo L X, Wu Q 2006 Chin. Phys. 1S 1755
  • 5Lopez-Sanchez A L, Schmerr L W 2007 Res. Nondestruct. Eval. 18 23
  • 6Schraerr L W 1998 Fundamentals of Ultrasonic Nondestructive Evaluation——A Modeling Approach (New York:Plenum) p414
  • 7Lopez-Sanchez A L, Kim H J, Schmerr L W, Sedov A 2005 J. Nondestr. Eval. 24 83
  • 8Wen J J, Breazeale M A 1988 J. Acoust. Soc. Am. 83 1752
  • 9Kim H J, Schmerr L W 2006 J. Acoust. Soc. Am. 119 1971
  • 10Huang D H, Breazeale M A 1999 J. Acoust. Soc. Am. 106 1771

二级参考文献16

共引文献5

同被引文献38

  • 1赖溥祥,张碧星,汪承灏.环形相控阵换能器辐射和反射声场[J].声学学报,2007,32(3):212-220. 被引量:23
  • 2吴迪,李明轩,王小民,成跃.横波直探头的暂态辐射声场[J].声学学报,2007,32(4):304-309. 被引量:5
  • 3于洁,章东,刘晓宙,龚秀芬,宋富先.圆锥面PVDF聚焦换能器的非线性声场理论及实验研究[J].物理学报,2007,56(10):5909-5914. 被引量:6
  • 4A RAMOS, A RUIZ, J L SAN EMETER[O, Pspice circuital modeling of ultrasonic imaging transceivers including frequen~'y - Dependent acoustic losses and signal distortions in electroni( sta- ges[ J]. Uhrasonics, 2006, (44) :995-1000.
  • 5ANA LILIA LOPEZ-SANCHEZ. Ultrasonic system models and measurements[ D]. Iowa: Iowa State University, 2005:99-128.
  • 6C DANG, L W SCHMERR, J R A SEDOV. Modeling and measuring all the elements of an ultrasonic nondestructive evalu- ation system i: modeling foundations[ J]. Res Nondestr Eval, 2002, 14:141-176.
  • 7C DANG, L W SCHMERR, J R A SEDOV. Ultrasonic trans- ducer sensitivity and model-based transducer characterization [ J]. Res Nondestr Eval, 2002, 14:203-228.
  • 8C DANG, L W SCHMERR, J R A SEDOV. Modeling and measuring all the elements of an ultrasonic nondeslructive evalu- ation system II: modeling fbundations[ J]. Res Nundestr Eval, 2002, 14:177-201.
  • 9HKIM, S J SONG, S S LEE, et al. A study of the couplant effects on contact ultrasonic testing[ J]. Korean Soc Nondestmet Test, 2002, 22(6):621-626.
  • 10Calmon P.Trends and stakes of NDT simulation.Journal of Nondestructive Evaluation,2012;31(4):339-341.