期刊文献+

心导管术后经皮血管缝合装置的临床研究

Clinical study of Suture Mediated Closure System after cardiac catheterization
下载PDF
导出
摘要 目的比较心导管术拔鞘管后,采用经皮血管缝合器(Perclse)止血与人工压迫止血的效果。方法1182例患者在心导管术后,分为血管缝合组(共588例,其中冠状动脉造影290例,介入治疗298例)和手法压迫组(共594例,其中冠状动脉造影300例,冠状动脉介入术294例),分别应用Perclose止血和手法压迫止血,观察止血时间、卧床时间和并发症。结果血管缝合组和手法压迫组比较,止血时间和卧床时间明显缩短,两组并发症有显著性差异,Perclose实施成功率95.30%。结论心导管术后应用经皮血管缝合器缩短了止血时间和卧床时间,减少了患者的痛苦和并发症。 Objective To assess the efficacy of Suture Mediated Closure System device (Perclose) in patients after cardiac catheterization procedures. Methods 1182 patients who underwent cardiac catheterization were divided into Perclose group (588 cases,290 cases underwent coronary angiography,298 cases underwent coronary interventional procedures) and manual compression group (594 cases,300 cases underwent coronary angiography,294 cases underwent coronary interventional procedures). The hemostasis time,time to ambulation and vascular complications were compared between the two groups. Results A significant reduction in time to achieve hemostasis and time to ambulation was associated with use of the Perclose. The incidencerate of complications was reduced in Perclose group. The successful hemostasis rate by Perclose device was 95.3%. Conclusion Suture mediated closure system can short significantly the time of hemostasis and lying in bed in patients who underwent cardiac catheterization.
出处 《中国临床保健杂志》 CAS 2008年第4期368-370,共3页 Chinese Journal of Clinical Healthcare
关键词 心脏导管插入术 止血 手术 外科缝合器 Heart catheterization Hemostatic,surgical Surgical staplers
  • 相关文献

参考文献6

  • 1[1]Gerckens U,Cattleaens N,Lampe EG,et al.Management of arterial duncture site after catheterization procedure:evaluating a suture-mediated closure device[J].Am J Cardiol,1999,83(12):1658-1662.
  • 2[2]Ricci MA,Trevisani GT,Pilcher DB,et al.Vascular complications of cardiac catheterization[J].Am J Surg,1994,167(4):375-378.
  • 3[3]Nasser TK,Mohler ER 3rd,Wilensky RL,et al.Peripheral vascular complications following coronary interventional procedures[J].Clin Cardiol,1995,18(11):609-614.
  • 4[6]Sanbor TA,Gibbs HH,Brinker JA,et al.Amulticenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty[J].J Am Coll Cardiol,1993,22(5):1273-1279.
  • 5[7]Webb JG,Carere RG,Dodek A.Collagen plug hemostatic closure of arterial puncture sites following implantation of coronary stents[J].Cathet Cardiovasc Diagn,1993,30(4):314-316.
  • 6[8]Messina LM,Brothers TE,Wakefield TW,et al.Clinical characteristics and surgical management of vascular complications in patients undergoing catheterization:interventional versus diagnostic procedures[J].J Vasc Surg,1991,13(5):593-600.