期刊文献+

基于个性化模型的人眼色差对视功能影响的研究(英文) 被引量:1

Study on Influence of Chromatic Aberrations on Vision Performance Based on Individual Eye Model
下载PDF
导出
摘要 利用光学设计软件Zemax,对人眼色差对视功能的影响进行了研究.对构建的个性化人眼模型进行离焦、像散和高阶像差矫正的模拟.视觉效果的提高受到了色差的很大限制.在中、高空间频率处,自然光下的调制传递函数约为单色光下的50%.在自然光下,传统视觉矫正能够获得1.2的视力,个性化视觉矫正能够获得1.5的视力,还远远达不到人们所期望的超视觉. The influence of ocular chromatic aberrations on vision performance was investigated based on individual eye model. The correction of the defocus, astigmatism and higher-order aberrations of human eye was simulated with the optical design software Zemax. Vision improvement achieved by vision correction is restricted considerably by the chromatic aberrations of human eye. At middle and higher spatial frequency, the MTF (modulation transfer function) in natural light is about 50% of that in monochromatic light. In natural light, visual acuity of 1.5 is achieved by customized vision correction theoretically, as compared with the acquired visual acuity of 1.2 by conventional correction, which is far away from the expected super-vision.
出处 《光子学报》 EI CAS CSCD 北大核心 2008年第8期1612-1616,共5页 Acta Photonica Sinica
基金 National Natural Science Foundation(60438030) Colleges and Universities Special Scientific Pesearch Foundation of Doctoral Subject Spot
关键词 个性化眼模型 色差 光学传递函数 视力 ZEMAX Individual eye model Chromatic aberrations Modulation transfer function Visual acuity, Zemax
  • 相关文献

参考文献4

二级参考文献40

  • 1全薇,王肇圻,宋贵才,凌宁,傅汝廉.用SVGA1薄膜晶体管液晶显示器矫正人眼波像差[J].光子学报,2004,33(12):1445-1448. 被引量:12
  • 2王玲,金成鹏.视网膜到大脑系统视力检测技术及其临床应用[J].生物医学工程与临床,2005,9(1):49-52. 被引量:11
  • 3李金海,游光华.新型激光视网膜MTF测定仪的光学设计[J].应用激光,1995,15(1):39-40. 被引量:5
  • 4[1]Pantazis M.Visual instrumentation.New York:McGraw-hill,1999:106~110
  • 5[2]Blaker J W.Toward an adaptive model of the human eye.J Opt Soc Am,1980,70(2):220~223
  • 6[3]Lotmar W.Theoretical eye model with aspherics.J opt Soc Am,1971,61(11):1522~1529
  • 7[4]Kooijman A C.Light distribution on the retina of a wide-angle theoretical eye.J Opt Soc Am,1983,73(11):1544~1550
  • 8[5]Navarro R,Santamaria J,Bescos J.Accommodation-dependent model of the human eye with aspherics.J Opt Soc Am,(A),1985,2(8):1273~1281
  • 9[6]Liou Hwey-Lan,Brennan N A.Anatomically accurate,finite modeleyt for optical modeling.J Opt Soc Am(A),1997,14(8):1684~1695
  • 10[7]Noll R J.Zernike polynomials and atmospheric turbulence.J Opt Soc Am,1976,66(3):207~211

共引文献36

同被引文献15

  • 1毕宏生.对比敏感度在眼科的临床应用[J].中华眼科杂志,2004,40(9):645-648. 被引量:58
  • 2王玲,金成鹏.视网膜视力计及其临床应用[J].临床眼科杂志,2004,12(6):564-567. 被引量:3
  • 3安连生.应用光学[M].3版.北京:北京理工大学出版社,1997:104-111.
  • 4HOOD D C,FINKELSTEIN M A.Sensitivity to light[M]//BOFF K R,KAUFMAN L,THOMAS J P.Handbook of perception and human performance,volume 1:sensory processes and perception[M].New York:John Wiley & Sons,1986:874-875.
  • 5GOODMAN J W.Introduction to fourier optics[M].New York:McGraw-Hill Inc,1968.
  • 6MING Liu,WANG Zhao-Qi,WANG YAN,et al.The study of wavelength-dependent wavefront aberrations based on individual eye model[J].Optik,2008,119:383-387.
  • 7HUBEL D H.Eye,brain,and vision[M].Scientific American Library,1988:162-164.
  • 8CAMPBELL F W,GREEN D G.Optical and retinal factors affecting visual resolution[J].J Physiol,1965,181:576-593.
  • 9CAMPBELL F W,ROBSON J G.Application of fourier analysis to the visibility of gratings[J].J Physiol,1968,197:551-566.
  • 10FELIPE A,ARTIGAS J M,PONS A M.Human contrast sensitivity in coherent Maxwellian view:effect of coherent noise and comparison with speckle[J].JOSA,1997,14(5):972-983.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部