简要介绍了中国首台引进型300 MW CFB锅炉主要技术参数,重点对影响白马300 MW CFB锅炉启动耗油的因素进行了分析,并提出了机组启动节能降耗的对策措施,为大型CFB锅炉启动节能降耗提供了依据,值得推广借鉴。
In this artical , it is introduced the main technology parameters of the first introduce - type 300MWCFB boiler in our country, analysis the elements, of which influenced the Bai - Ma 300MWCFB boiler oil consumption under start - up , for that to advance the relative manners to save energy and reduce consumption of the unit. It is afford the basis to save energy and reduce comsuption under start - up of the CFB boiler ,worth to popularize and make use of.
出处
《四川电力技术》
2008年第4期16-17,91,共3页
Sichuan Electric Power Technology
关键词
循环流化床锅炉
启动
节能降耗
原因分析
优化措施
CFB boiler
Start- up
Save energy and reduce consumption
cause analysis
Optimization measures.