期刊文献+

DG1025/18.2-II4型锅炉风粉混合器改造探讨 被引量:1

The Discussion of Wind-pulverize Mixer Reconstruction of DG-1025/18.2-II4 Type Boiler Luo
下载PDF
导出
摘要 针对四川巴蜀江油燃煤发电有限公司2×300 MW机组在投运初期锅炉给粉均匀性差的问题,找出了风粉混合器结构不合理是导致给粉均匀性差的原因。经分析研究利用引流原理对原来安装的风粉混合器进行改进,消除托粉现象,提高进入炉膛给粉均匀性,经过改进后的风粉混合器已使用半年多,应用结果表明其特性良好,提高了锅炉燃烧的稳定性和经济性。 For the problem of 2×300MW unit in the Sichuan Bashu coal -fired generate Co. , Ltd during the commission primary period on the uniformity difference of the boiler coal - pulverize feed, to find out that the unreasonable structure of the wind - pulverize mixer is the reason of the uniformity difference. Through the analysis and the research, Based on the draught principle ,we have improved the original wind - pulverize mixer, resolved the phenomenon of the coal - pulverize leakage, and improved the uniformity of the coal - pulverize feed. After the half of the year, the results of the application in the improvement are well, improve the steady and the economic of the boiler burning.
作者 罗强骏
出处 《四川电力技术》 2008年第4期21-23,63,共4页 Sichuan Electric Power Technology
关键词 锅炉 给粉均匀性 煤粉混合器 改进 Boiler Uniformity of the boiler coal - pulverizes feed Wind - pulverize mixer amelioration.