期刊文献+

Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized on L-glutathione self-assembled monolayers

Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized on L-glutathione self-assembled monolayers
下载PDF
导出
摘要 A novel hydrogen peroxide biosensor has been fabricated based on covalently linked horseradish peroxidase (HRP) onto L- glutathione self-assembled monolayers (SAMs). The SAMs-based electrode was characterized by electrochemical methods, and direct electrochemistry of HRP can be achieved with formal potential of-0.242 V (vs. saturated Ag/AgCl) in pH 7 phosphate buffer solution (PBS), the redox peak current is linear to scan rate and rate constant can be calculated to be 0.042 s^-1. The HRP-SAMs- based biosensors show its better electrocatalysis to hydrogen peroxide in the concentration range of 1 × 10^-6 mol/L to 1.2 × 10^-3 mol/L with a detection limit of 4 × 10^-7 mol/L. The apparent Michealis-Menten constant is 3.12 mmol/L. The biosensor can effectively eliminate the interferences of dopamine, ascorbic acid, uric acid, catechol and p-acetaminophen. A novel hydrogen peroxide biosensor has been fabricated based on covalently linked horseradish peroxidase (HRP) onto L- glutathione self-assembled monolayers (SAMs). The SAMs-based electrode was characterized by electrochemical methods, and direct electrochemistry of HRP can be achieved with formal potential of-0.242 V (vs. saturated Ag/AgCl) in pH 7 phosphate buffer solution (PBS), the redox peak current is linear to scan rate and rate constant can be calculated to be 0.042 s^-1. The HRP-SAMs- based biosensors show its better electrocatalysis to hydrogen peroxide in the concentration range of 1 × 10^-6 mol/L to 1.2 × 10^-3 mol/L with a detection limit of 4 × 10^-7 mol/L. The apparent Michealis-Menten constant is 3.12 mmol/L. The biosensor can effectively eliminate the interferences of dopamine, ascorbic acid, uric acid, catechol and p-acetaminophen.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第8期955-958,共4页 中国化学快报(英文版)
关键词 Direct electrochemistry Horseradish peroxidase BIOSENSOR Self-assembled monolayer Hydrogen peroxide Direct electrochemistry Horseradish peroxidase Biosensor Self-assembled monolayer Hydrogen peroxide
  • 相关文献

参考文献9

  • 1[1]M.J.Eddowes,H.A.O.Hill,J.Chem.Soc.Chem.Commun.21 (1977) 771.
  • 2[2]A.Ulman,Chem.Rev.96 (1996) 1533.
  • 3[3]J.F.Rusing,Acc.Chem.Res.31 (1998) 363.
  • 4[4]A.L.Ghindilis,P.Atanasov,E.Wilkins,Electroanalysis 9 (1997) 661.
  • 5[5]E.Katz,I.Willner,Chem.Phys.Chem.5 (2004) 1084.
  • 6[6]C.Y.Liu,G.H.Lu,L.Y.Jiang,X.C.Zhou,Electroanalysis 18 (2006) 291.
  • 7[7]G.X.Ma,T.H.Lu,Y.Y.Xia,Bioelectrochemistry 71 (2007) 180.
  • 8[8]E.Laviron,L.Roullier,J.Electroanal.Chem.443 (1998) 195.
  • 9[9]R.A.Kamin,G.S.Willson,Anal.Chem.52 (1980) 1198.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部