摘要
通过测试湿筛混凝土的热物理参数来评价拱坝大体积混凝土的热学特性,必然与大坝实际混凝土存在差异。对拱坝全级配大体积混凝土热物理参数的试验研究结果表明:拱坝全级配大体积混凝土的热物理参数存在着一定的尺寸效应,用湿筛小试件混凝土的热物理参数表征水工全级配大体积混凝土的热学特性显然是不真实的。
To assess arch dam mass concrete themophysics properties by testing those of the concrete wet screened specimens the test results are certainly different from the actual parameters of the concrete. Testing the complete grading mass concrete indicates that the thermophysics parameters of arch dam complete grading concrete are with size effect. Obviously, it is untrue to represent these thermal properties of the hydraulic complete grading concrete by use of the thermophysics parameters of the concrete wet screened specimens.
出处
《水电站设计》
2008年第3期15-18,共4页
Design of Hydroelectric Power Station
关键词
拱坝
大体积砼
热物理参数
砼试验
arch dam
mass concrete
thermal properties
concrete test