期刊文献+

PZT压电陶瓷的总剂量辐照效应实验研究 被引量:4

Research on Total Dose Radiation Effect of PZT Piezoelectric Material
下载PDF
导出
摘要 采用传统固相反应法制备PZT压电陶瓷材料,并制作成平行平板无源电容器结构。在ELV-8电子直线加速器上对其进行总剂量辐照效应实验,对辐照前后PZT材料的介电和压电性能参数进行了测试和比较。实验结果表明,PZT材料平行平板电容器的压电性能抗总剂量水平可达2×108rad(Si),领先国际水平。 Lead zirconate titanate (PZT) piezoelectric materials were prepared by the traditional solid phase reaction method and the passive capacitor of parallel slab was manufactured using this material. We have experimented on the total dose radiation effect of the PZT ferroeLectric material capacitors with the ELV-8 electron beeline acceLer- ator. The piezoelectric/dielectric performance parameters of capacitors before and after radiation were tested and compared, and the experiment results indicate that the anti-total dose radiation capability of these capacitors were up to 2×10^8 Rad (Si), being in the lead of world level.
出处 《压电与声光》 CSCD 北大核心 2008年第5期585-587,共3页 Piezoelectrics & Acoustooptics
关键词 压电材料 压电常数 介电常数 总剂量辐照效应 piezoelectric material piezoelectric constant, dielectric constant total dose radiation effect
  • 相关文献

参考文献4

  • 1田莳.铁电材料研究进展及其在飞行器上的应用[J].航空学报,2000,21(C00):6-10. 被引量:5
  • 2SCHWAK J R, NASBY R D, MILLER S L. Total dose radiation-induced degradation of thin film ferroelectric capacitors[J]. IEEE Trans Nucl Sci, 1991, 37(6): 1703-1707.
  • 3SCOTT J E, ARAUJO C A, BRETT H. Radiation effects on ferroelectric thin-film memories: retention failure mechanisms[J]. J APPI Phys, 1989, 22 (8) : 1444-1449.
  • 4COLC Y M, MUSSEAU O, LERAY J L. A study of radiation vulnerability of ferroelectric material and devices[J]. IEEE Trans Nucl Sci, 1994, 41 (3): 495- 499.