摘要 目的:研究陶瓷型人工全髋关节置换治疗股骨头缺血性坏死的中短期疗效,以探讨此假体的临床应用价值。方法:对陶瓷-陶瓷非骨水泥型假体23例28髋进行随访,应用Harris评分标准进行功能评价,应用股骨Gruen与髋臼Delee-Charnly分区方法进行影像学评价。结果:Harris评分可见显著性差异;影像学上无明显的假体松动。结论:对于股骨头缺血性坏死患者,新型的陶瓷-陶瓷假体随访2年效果良好,影像学表现无明显松动。 Objective: To study the short and medium-term effect of ceramic hip prosthesis for avascular necrosis of the femoral head(ANFH) in order to investigate its clinical value.Methods: Twenty-three cases(28 hips) of ANFH treated with ceramic hip arthroplasty were followed up.The postoperative functional assessment was evaluated by Harris scale,and imaging assessment was done by Gruen's zonal method for the stem and the zonal classification of Delee-Charnly for the cup implants.Results: Obvious functional improvements were obtained according to Harris scale.Meanwhile,there was no obvious prosthesis loosening based on imaging assessment.Conclusion: Ceramic hip replacement might be a satisfactory treatment for patients with ANFH.
出处 《中国中医骨伤科杂志》 CAS 2008年第8期9-11,共3页 Chinese Journal of Traditional Medical Traumatology & Orthopedics
关键词 陶瓷 置换 股骨头缺血性坏死 Ceramic Replacement Hip Avascular necrosis of the femoral head
  • 相关文献

参考文献11

  • 1XENAKIS T A, GELALIS J,KOUKOUBIS T A,et al. Cementless hip arthroplasty in the treatment of patients with femoral head necrosis[J].Clin Orthop Relat Res. 2001 May:(386):93-9.
  • 2GRUEN T A, MCNEICE G M, AMSTUTZ H C. “Modes of failure” of cemented stem type femoral components; a radiographic analysis of loosening[J].Clin Orthop Relat Res. 1979 Jun;(141):17-27.
  • 3DELEE J G, CHARNLEY J. Radiological demarcation of cemented sockets in total hip replacement[J]. Clin Orthop Relat Res. 1976 Nov-Dec: (121 ):20-32
  • 4CUCKIER J M, BEARCROFT J, ASGIAN C M. Femoral head technologies to reduce polyethylene wear in total hip arthroplasty [J].Clin Orthop Relat Res. 1995 Aug;(317):57-63.
  • 5HANNOUCHE D, NICH C, BIZOT P,et al. Fractures of ceramic hearings: history and present status[J]. Clin Orthop Relat Res. 2003 Dec;(417):19-26.
  • 6CLARKE I C,GUSTAFSON A, JUNG H,et al. Hip simulator ranking of polyethylene wear: comparisons between ceramic heads of different sizes[J]. Acta Orthop Scand. 1996 Apr;67(2):128- 32.
  • 7温宏,刘忠堂,张宇,池永龙.陶瓷髋关节假体现状[J].临床骨科杂志,2003,6(1):91-94. 被引量:8
  • 8Garino J P. Modern ceramic-on-ceramic total hip systems in the United States: early results, Clin Orthop Relat Res[J], 2000 Oct; (379):41-7
  • 9杨述华,胡勇,陈中海,杜靖远,杨操,许伟华,肖宝均,邵增务,李进,胡天喜,汪岚.空心侧孔椎弓根螺钉添加聚甲基丙烯酸甲酯骨水泥的生物力学研究[J].中华创伤杂志,2002,18(1):17-32. 被引量:30
  • 10王旭,顾湘杰,鲍根喜,陈飞雁,黄加张.陶瓷-陶瓷人工髋关节初步应用结果[J].骨与关节损伤杂志,2004,19(7):448-450. 被引量:11

二级参考文献64

  • 1[1]Manley MT, Serekian P. Wear debris [J]. Clin Orthop, 1994; (298):137~146
  • 2[2]Schmalzried TP, Guttmann D, Grecula M et al. The relationship between the design, position and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis [J]. J Bone Joint Surg Am, 1994;76(5):677~688
  • 3[3]Marti A. Inert bioceramics (Al2O3, ZrO2) for medical application [J]. Injury, 2000; 31(Suppl 4): 33~36
  • 4[4]Clarke IC, Gustafson A, Jung H et al. Hip-simulator ranking of polyethylene wear:comparisons between ceramic heads of different sizes [J]. Acta Orthop Scand, 1996;67(2):128~132
  • 5[5]Lerouge S, Huk D, Yahia LH et al. Characterization of in vivo wear debris from ceramic-ceramic total hip arthroplasties [J]. J Biomed Mater Res,1996;32(4):627~633
  • 6[6]Lerouge S, Huk O, Yahia L et al. Ceramic-ceramic and metal-polyethylene total hip replacements:comparison of pseudomembranes after loosening [J]. J Bone Joint Surg Br, 1997;79(1):135~139
  • 7[7]Sharkey PF, Hozack WJ, Dorr LD et al. The bearing surface in total hip arthroplasty: evolution or revolution[C]. Instr Course Lect, 2000;49:41~56
  • 8[8]Fritsch EW, Gleitz M. Ceramic femoral head fractures in total hip arthroplasty [J]. Clin Orthop,1996;(328):129~136
  • 9[9]Semlitsch M, Willert HG. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements [J]. Proc Inst Mech Eng,1997; 211(1):73~88
  • 10[10]Clarke IC, Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear [J]. Clin Orthop, 2000; (379):34~40

共引文献45