分析了夹层玻璃合片室室内低湿环境控制特点,提出了适合低湿环境要求的低湿空气处理方案及其空调系统设计方案,结合工程实例对合片室空调系统的设计方法进行了总结。
Presented indoor thermal characteristics of a glass lamination room,which is full of low humidity air. Design schemes of low humidity air-handler and air-conditioning system air were also discussed. Based on an actual project ,design method of low humidity air-conditioning system for the glass lamination room was finally proposed.
出处
《制冷空调与电力机械》
2008年第4期29-31,共3页
Refrigeration Air Conditioning & Electric Power Machinery
关键词
夹层玻璃合片室空调
低湿环境
空气低湿处理
air-conditioning system for glass lamination room
indoor environment with low humidity air