期刊文献+

利用准二级循环提高跨临界CO_2热泵热水器性能 被引量:2

Improving Performance of Transcritical CO_2 Heat Pump Water Heater by Quasi Two-stage Cycle
下载PDF
导出
摘要 提出了一种全新的应用于热泵热水器的准二级跨临界CO2热泵循环。对其分析研究表明该循环可以有效降低压缩机的排气温度,提高热泵热水器的制热效率。这种热泵热水器尤其适用于寒冷地区。 An new technology quasi two-stage transcritical CO2 heat pump cycle is presented . The discharge temperature of compressor of this cycle can be reduced availability, and the heating coefficient of performance can be increased through investigation. This heat pump water heater can be applied in cold region.
出处 《流体机械》 CSCD 北大核心 2008年第8期66-69,共4页 Fluid Machinery
基金 国家科技支撑计划-低品位能源高效应用关键技术研究子课题:CO2空气源热泵热水机组开发(2006BAJ01A10)
关键词 热泵热水器 准二级跨临界CO2热泵循环 排气温度 制热效率 heat pump water heater quasi two-stage cycle transcritical CO2 heat pump cycle discharge temperature heatingcoefficient of performance.
  • 相关文献

参考文献11

  • 1Petter Neksa. COs-heat pump water heater: characteristics, system design and experimental results [ J ]. Int. J. Refrig. , 1998,21 (3) : 172-179.
  • 2Pettersen J, Hafner A, Skaugen G. Development of compact heat exchangers for CO2 air-conditioning systems [ J ]. International Journal Refrigeration, 1998,21 (3) :180-193.
  • 3小国研作 安田弘 中山进.用于寒冷地区的热泵空调机[P].中国:96102111.X.1996.12.25.
  • 4Mukaiyama H, Kuwabara. Experimental results and evaluation of residential CO2 heat pump water [ A ]. In: 4th IIR Gustav Lorentzen conference on natural working fluids [ C ]. Purdue University, USA,2000.67-74.
  • 5Saikawa M, Hashimoto K, Kusakari K, etal. Development of prototype of CO2 heat water heater for residential use [ A]. In :4th IIR Gustav Lorentzen conference on natural working fluids [ C ]. Purdue University, USA,2000.51 -58.
  • 6黄冬平,丁国良,张春路.不同跨临界二氧化碳制冷循环的性能比较[J].上海交通大学学报,2003,37(7):1094-1097. 被引量:27
  • 7Robinson D M, Groll E A. Efficiencies of transcritical cycles with and without an expansion turbine [ J ]. International Journal of Refrigeration, 1998,21 ( 7 ) : 577- 589.
  • 8Liao S M ,Zhao T S,Jakobsen A. A conelation of optimal heat rejection pressures in transcritical carbon dioxide cycles [ J ]. Applied Thermal Engineering, 2000, 20(9) :831-841.
  • 9Khan J U R,Zubair S M. Design and rating of a two- stage vapour compression refrigeration system[ J]. Energy,1998,23 (10) :867-878.
  • 10Chen J, Wu C. Optimization of a two-stage combined refrigeration system [ J ]. Energy Convers. Manage, 1996,37 (3) :353-358.

二级参考文献5

  • 1McEnaney R P, Boewe D E, Yin J, et al. Experimetnal comparison of mobile A/C systems when operated with transcritical CO2 versus conventional R134a[A].Proceedings of the 1998 International Refrigeration Conference at Purdue [C]. Indiana, USA: Purdue University West Lafayette, 1998. 145--150.
  • 2Heyl P, Kraus W E, Quack H. Expander-compressor for a more efficient use of CO2 as refrigernt[A]. Natural Working Fluids'98 IIR-Gustav Lorentzen Conference[C]. Norway: Technical Session 4B Oslo, 1998.
  • 3Douglas M R, Eckhard A G. Efficiencies of transcritical CO2 cycles with and without an expansion turbine[J]. International Journal of Refrigeration, 1998, 24(7):577--589.
  • 4马一太,杨昭,吕灿仁.CO_2跨临界(逆)循环的热力学分析[J].工程热物理学报,1998,19(6):665-668. 被引量:42
  • 5丁国良,黄冬平,张春路,陈江平,陈芝久.跨临界循环二氧化碳汽车空调研究进展[J].制冷学报,2000,21(2):7-13. 被引量:21

共引文献27

同被引文献14

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部