摘要 采用多接收电感耦合等离子体质谱(MC-ICPMS),用同位素稀释法测量了反应堆辐照后核燃料中的裂变产物148Nd。通过2个标准物质对仪器的稳定性进行检验,得到仪器的2个校正系数K值相差十万分之一。以高纯天然钕为基准稀释剂,用同位素稀释质谱标定浓缩144Nd试剂的质量分数,然后以它作为稀释剂,测量裂变产物148Nd的同位素丰度和质量分数。结果表明,148Nd丰度为0.0887±0.0012,148Nd质量分数为(4.65±0.04)ng/g。 The isotopic abundance and mass fraction of the fission product ^148Nd in the irradiated nuclear fuel were measured with ID-MC-ICPMS. The stability of mass spectrometry instrument was tested using two kinds of standard materials and the difference of two correction factors was less than 0. 001%. The mass fraction of enriched isotope ^144Nd was determined by using the high pure natural neodymium as the spike. Then the mass fraction of ^148Nd in the irradiated nuclear fuel was determined by the certified enriched ^144Nd as the spike. The isotopic abundance and mass fraction of ^148Nd in the fission products is 0. 088 7±0. 001 2 and (4.65± 0.04) ng/g respectively.
出处 《核化学与放射化学》 EI CAS CSCD 北大核心 2008年第3期174-177,共4页 Journal of Nuclear and Radiochemistry
  • 相关文献

参考文献8

  • 1高淑琴,李思林.用质谱法测定反应堆元件燃耗监测核素148Nd的丰度和含量[R].中国核科技报告,1992,00:611-623.
  • 2邓中国,赵墨田,高淑琴,李思林.用质谱法测定反应堆元件的燃耗[J].原子能科学技术,1989,23(1):44-49. 被引量:3
  • 3Mariana A V, Anderson S R, Lfcia F D, et al. Determination of Hg and Se in Biological Materials by Chemical Vapor Generation Electrothermal Vapori- zation Inductively Coupled Plasma Mass Spectrometry Using Isotope Dilution Calibration After Micro- wave-Assisted Digestion With Aqua Regia [J]. J Braz Chem Soc, 2006, 17(5): 923-928.
  • 4Diemer J, Quetel C R, Taylor P D P. Comparison of the Performance of Different ICP-MS Instruments on the Measurement of Cu in a Water Sample by ICP-IDMS[J]. J Anal At Spectrom, 2002, 17: 1 137-1 142.
  • 5Watter R L, Eberhandt Jr K R, Beary E S, et al. Protocol for Isotope Dilution Using Inductively Cou- pled Plasma-Mass Spectrometry (ICP-MS) for the Determination of Inorganic Elements[J]. Metrologia, 1997, 34: 87-96.
  • 6Fortunato G, Wunderli S. Evaluation of the Combined Measurement Uncertainty in Isotope Dilution by MC-ICP-MS[J]. Anal Bioanal Chem, 2003, 377 (1) : 111-116.
  • 7王军,赵墨田.同位素稀释质谱法测定国际比对水样中的铅[J].分析化学,1998,26(4):418-421. 被引量:10
  • 8周涛,赵墨田,李金英,王军,赵永刚,张继龙,逯海,方向.绝对质谱法测量钐同位素丰度[J].分析化学,2005,33(9):1272-1274. 被引量:3

二级参考文献10