运用度日法和简化温频法对水源热泵空调系统全年负荷进行分析与比较,采用拟合的热泵机组性能曲线,分析了不同温频下热泵机组的实际输入功率和COP值,计算出建筑物全年总能耗。
By using time-history and simplified temperature-frequency methods, the annual loads required in water source heat pump air conditioner system were analyzed and compared. The regressed property curve of heat pump was used to analyze the actual input power and COP value of heat pump under different temperature-frequency. In this way, the annual total energy consumption of the building can be obtained.