摘要 本文在常规火电厂主蒸汽温度自动控制方案的基础上,对200MW乏气送粉机组的特性进行了分析,结合锅炉主要参数与主蒸汽温度自动控制的相互关系,以及相关的工艺要求,提出了一种新的优化方案。 This article analyzes the characteristics of 200MW power generating unit with pneumatic coal dust conveying system which is driven by air exhaust on the basis of the main steam temperature automatic control scheme of conventional thermal power plant. The author proposes a new optimized scheme in combination with the interrelation between the boiler main parameters and the main steam temperature automatic control and the technological requirements related.
作者 彭超
出处 《自动化信息》 2008年第8期76-77,共2页 Automation Information
关键词 燃煤电厂 乏气送粉 主蒸汽温度控制 Coal-fired Power Plant Pneumatic Coal Dust Conveying System by Air Exhaust Main Steam Temperature Control