电厂温度多路调制系统升级改造

Upgrade and reformation of multichannel temperature modulation system of power plant
下载PDF
导出
摘要 分析了沙角C电厂^#1机组温度数据采集系统的特点及其存在的缺陷,介绍了针对该系统的改造方案及其选择过程,阐述了该系统改造后的特点和功能,并与改造前的状况进行了比较,得出了系统改造成功的结论。 The features and drawback of temperature data acquisition system used in the unit No1 of Shajiao C Power Plant were analyzed, and the reformation scheme of the system and its selection were described, The features and function of the reformed system were expounded comparing with that before reformation, which shows that the system reformation was successful.
作者 巫光峰
机构地区 沙角C电厂
出处 《华电技术》 CAS 2008年第8期44-46,共3页 HUADIAN TECHNOLOGY
关键词 温度多路调制解调 IDBC分布式智能数据采集网络 升级改造 multichannel temperature modulation and demodulation IDBC distributed intelligent data acquisition system upgrade and reformation