摘要
介绍了新型(SD1146)绝缘系统的性能及结构试验,试验结果表明,采用混包结构较纯薄膜补强结构更适用SD1146绝缘系统,其绝缘系统达到了电机使用的基本要求,并针对云母带绕包线与SD1146系统相容性不佳问题,提出了技术改进的建议。
The performance of a new type of insulating system was presented and structural tests showed that SD1146 insulating system meets the basic requirements for motors in which mixed package structure used is better than single film-reinforced structure. The compatibility between mica tape lapped wire and SD1146 is not good. Some improvement suggestions were provided.
出处
《绝缘材料》
CAS
2008年第4期24-27,32,共5页
Insulating Materials
关键词
主绝缘
真空压力浸渍(VPI)
相容性
main insulation
vacuum pressure impregnation(VPI)
compatibility