期刊文献+

深圳现代商务大厦桁架转换层结构设计 被引量:6

Analysis and Design of Truss-transfer Story of Shenzhen Modern Commercial Building
原文传递
导出
摘要 现代商务大厦为超限高层建筑,结构总高度186.20m。在层6通过型钢混凝土桁架将上部外框架密柱转换为落地疏柱。针对桁架转换结构特点,研究了桁架转换层对结构整体抗侧刚度的影响,详细计算了桁架内力和转换层及其上层楼板的应力及分布,介绍了转换桁架及其上下层楼板的设计。计算结果表明,桁架转换具有传力明确,传力路径清楚,结构刚度、质量变化较为均匀等优点。 Shenzhen Modern Commercial Building is a high-rise building which exceeds the prescription of specification, the height of structure is 186.20m. The composite trusses(steel-concreted) are arranged on the sixth floor to transfer the external dense framed columns on the upper floors to the sparse columns on the lower floors. According to the traits of truss transferring structure, the affect to the lateral resist rigidity of entire structure was studied. The stress-diagrams of the truss, transferring floor and upper slab were analyzed detailedly, and the appropriate designs were also introduced. From the result, it was clear that the load-path of the truss is straightforward, and lack of change of the mess and structural rigidity between the floors.
出处 《建筑结构》 CSCD 北大核心 2008年第8期30-33,共4页 Building Structure
关键词 桁架转换 抗侧刚度 加强措施 高层建筑 transfer truss resist lateral rigidity strengthening measures high- rise building
  • 相关文献

参考文献1

二级参考文献17

  • 1ATCAO Seismic Evaluation and Retrofit of Conctete Buildings[R]. Applied Technology Council, 1996.
  • 2FEMA 273 NEHRP Guidelines for seismic Rehabilitation of buildings [R]. Federal Emergency Management Agency,1997.
  • 3SEAOC Vision 2000 a Framework for Performance-based Engineering [ R]. Structural Engineering Association d California,1995.
  • 4BSSC (1998) NEHRP Recommended provisions for seismic regulation of new buildings and other structures[R]. Report No: FEMA302, Washington, D. C.
  • 5FEMA 368 (2000) NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures [ R]. Federal Emergency Management Agency, Washington, D.C.
  • 6FEMA 355 (2000) State of the art report on connection performance [ R ]. Federal Emergency Management Agency, Washington, D. C.
  • 7FEMA 356 (2000) Prestandard and commentary for the seismic rehabilitation of buildings [R]. Federal Emergency Management Agency, Washington, D. C.
  • 8ICC (2003) Performance Code for Buildings and Facilities, International code council, 2003.
  • 9Building code of Australia (BCA), Australia building codes board, 1996.
  • 10周锡元.抗震性能设计与三水准设防[J].土木水利(台湾),2003,30(5).

共引文献222

同被引文献32

引证文献6

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部