摘要 通过对大唐信阳二期2×600 MW级超超临界机组工程主厂房布置格局、结构尺寸的优化设计,分析比较了不同布置方案对初投资、运行维护的影响。大唐信阳二期的主厂房布置方案在满足运行维护要求的前提下,可比容积达到了0.186m3/kW的先进水平,其优化设计的经验可供类似工程参考。 Based on optimized design of main power block configuration and structural sizes for Datang Xinyang 2×600 MW USC units project, phase II, the paper analyzes and compares the affects of different arrangement schemes on the primary investment, operation and maintenance. The main power block configuration scheme of Datang Xinyang, phase II project has reached advanced level of 0.186 m^3/kW comparable volume in conditions to meet the operation and maintenance requirements. Its design experiences can be referred for other similar projects.
机构地区 西北电力设计院
出处 《电力建设》 2008年第9期64-67,共4页 Electric Power Construction
关键词 主厂房布置 优化设计 单框架 体积指标 main powerblock configuration optimized design single frame volumetric index
  • 相关文献

参考文献4

  • 1西北电力设计院.大唐信阳二期工程《主厂房布置专题报告》.
  • 2汤蕴琳.大型火电厂设计优化思路[J].电力建设,2005,26(12):1-5. 被引量:18
  • 3火力发电厂设计技术规程(DL5000-2000)[S].北京:中国电力出版社.2001.
  • 4陈绍蕃.结构设计原理[M].北京:科学出版社,2001.

二级参考文献5

  • 1Feasibility study concerning application of established Danish high efficiency supercritical Benson boiler clean coal technology in China,FLS,-CPECC,July 2000.
  • 2The turbine of USC power plant,Retz1aff K.M.等,GE Power system,1997.
  • 3Steam generators for the next generation of power plants,aspects of design and operating performance,Franke J.等,Siemens AG,VGB Power Tech 12/99.
  • 4.论锅炉给水泵汽轮机在中国发电厂的应用.Hultgren K.J.,GE Power system,GER-3825 CH[Z].,1995..
  • 5.火电厂烟气脱硫技术及SCR脱硝装置预留方案专题技术研究[Z].中国电力工程顾问集团公司,2005-4..

共引文献19