摘要 插接式开关装置PASS,是将断路器、隔离开关/接地开关、数字式光电组合电流、电压传感器等组合在一个SF6气体封闭罐内,并通过绝缘套管与变电站的出线和母线相连接的新型组合电器。PASS的接线方式介于AIS与GIS之间。它既具有GIS的成套性强、抗严酷环境、可靠性高、维护量小等优点,又具有AIS的一次性投资小,安装简便、工期短,SF6气体用量少,检修、维护方便等优点。在目前电力建设工期短、现场安装条件恶劣、安装质量控制难度大的情况下,建议在变电站的改造和建设中使用PASS设备。 Plug-in switching (PASS) is a new type of combined switch, which combines circuit breaker, disconnector/earth switch, digital photoelectrical current and voltage sensors within one airtight SF6 can, and is connected with substation output line and bus-bar through insulated sleeves. PASS connection lies between AIS and GIS. It not only has advantages of GIS, such as easy to complete, withstanding harsh environment, reliable, and low maintenance, etc., but also has advantages of AIS, including low cost, easy to install, short construction time, low SF6 consumption, and easy to inspect and maintenance, etc. It is recommended that PASS equipments are first choice in substation upgrade and construction in circumstances of short construction time, harsh site condition, and hard to control installation quality.
作者 詹英华
出处 《电力建设》 2008年第9期84-86,共3页 Electric Power Construction
关键词 PASS GIS AIS 比较 建议 PASS GIS AIS comparison recommendation
  • 相关文献

参考文献6

  • 1国电博纳(北京)电气技术有限责任公司.插接式SF6气体绝缘开关设备[Z].2006.
  • 2詹英华.GIS母线现场安装的关键控制点分析.南方电网技术研究,2006,2(6):69-71.
  • 3PASSMOO72.5kV插接式开关装置[EB/OL].http://www.e-banner.com.cn/pass4.htm,2005.
  • 4对PASS(DCB型)室内方案的综合性评价[J/OL].(2004-5-16.)http://www.e-banner.com.cn/passl.htm.
  • 5谭振.PASS装置在220kV变电站中的应用[R].珠海:珠海电力设计院有限公司.2006.
  • 6云开电气集团有限公司(云南开关厂)PASSMO[Z].2006.

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部