新建建筑围护结构热质传递对室内温湿度环境的影响 被引量:12

Influences of Envelope Heat and Moisture Transfer of New Building on Indoor Temperature and Humidity
原文传递
导出
摘要 新建建筑第1年由于较大的内表面散湿量会影响室内的温湿度水平,严重的会引起围护结构内表面霉菌。为分析新建建筑第1年围护结构的湿传递对室内温湿度环境的影响,本文对哈尔滨地区新建建筑综合热质耦合传递进行了模拟,分别建立了围护结构和室内空气的质能平衡方程,并讨论了夏季不同的室内通风率对围护结构内表面散湿量及室内温湿度的影响,得出了几点重要结论。 Interior moisture release of new building in the first year would affect the indoor temperature and humidity and would result in mildew if serious. In order to analyze the influences of envelope heat and moisture transfer of new building on indoor temperature and humidity, the integrate heat and moisture coupled transfer of a new building in Harbin was simulated. The heat and mass transfer conservation equations of porous envelope and indoor air were established, respectively. Furthermore, the effects of different indoor ventilation rates on interior moisture release of envelope and indoor temperature and humidity were discussed and some useful conclusions were achieved.
出处 《建筑科学》 北大核心 2008年第8期94-97,共4页 Building Science
关键词 新建建筑 热质传递 室内温湿度 内表面散湿量 通风率 new building, heat and moisture transfer, indoor temperature and humidity, interior moisture release, ventilation rate
  • 相关文献

参考文献5

  • 1肖石.霉菌一个值得注意的问题[J].中国建筑防水,2003(6):32-34. 被引量:8
  • 2Hosni MH, Sipes JM. Experimental results for diffusion and infiltration of moisture in concrete masonry walls exposed to hot and humid climates[ J]. ASHRAE Transactions, 1999,105(2) : 191 - 203.
  • 3我国新一轮土地详查在即[EB/OL].[2005-06-28].http://www.ycwb.com/gb/content/2005-06/28/content_930232.htm.
  • 4Achilles Karagiozis, Mikael Salonvaara. Hygrothermal system performance of a whole building [ J ]. Building and Environment, 2001,36(6) :779 - 787.
  • 5Lotz WA. Moisture problem in buildings in hot humid climates [ J ]. ASHRAE Journal, 1989, (4) :26 - 27.

共引文献7

同被引文献89

  • 1汤伟方,吕令毅.夹层玻璃蜕变的可靠性分析[J].低温建筑技术,2006,28(3):53-55. 被引量:2
  • 2包剑,郑晓红,代彦军.硅胶用于调节室内湿度的可行性研究[J].暖通空调,2006,36(11):54-57. 被引量:4
  • 3张华玲,刘朝,刘方,付祥钊.地下洞室多孔墙体热湿传递的数值模拟[J].暖通空调,2006,36(12):9-13. 被引量:12
  • 4杨延萍,丁云飞,康素杰.关于湿度[J].建筑知识,2007,27(1):17-18. 被引量:3
  • 5SONG F T, ZHAO B, YANG X D. A new approach on zonal modeling of indoor environment with mechanical ventilation[J]. Building and Enviro, 2008,43:278-286.
  • 6PLATHNER P, WOLOSZYN M. Interzonal air and moisture transport in a test house: experiment and modeling[J]. Building and Enviro , 2002,37:189-199.
  • 7SIMONSON C J, SALONVAARA M. Moderating indoor conditions with hygroscopic building materials and outdoor ventilation[J]. ASHRAE Trans, 2004,110(2):804-819.
  • 8TOFTUM J, JORGENSEN A S, FANGE P O. Upper limits of air humidity for preventing warm respiratory discomfort[J]. Energy and Buildings, 1998,28 : 15-23.
  • 9FANG L, GLAUSEN G G, FANGER P O. Impact of temperature and humidity on the perception of indoor air quality during immediate and longer whole-body exposures[J]. Indoor Air, 1998 (8) :276-284.
  • 10张克崧,周吕军,陆耀庆.GB50019-2003,采暖通风与空气调节设计规范[S].北京:中国计划出版社,2003.

引证文献12

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部