摘要 文中研究了用衍射做透镜列阵与焦面探测器相耦合来提高探测系统的能量利用率,从而改善其信噪比等整机性能及轻量化前置光学系统的原理。结论表明,该方法的有效性决定于衍射微透镜列阵的F/#和衍射效率ηde及其对焦面的能量接收率及kp,F/#越小,ηde与kp越大,系统性能改善越好。 The principle of improving signal-noise ratio of detector and lighteningfore optics through increasing the energy utilization ratio of detector, which is realizedby matching a diffraction microlens array (DMLA) in front of detector array, is pre-sented in this paper. The conc1usion demonstrates that the effectiveness of the methoddepends on the DMLA's F/ #, diffraction efficiency Vde and receiving factor kp to theoptic energy gathered on focal plane, the lower the F/ # is, and the higher the otherparameters arel the properties of detector can be improved better.
出处 《红外与激光工程》 EI CSCD 1997年第6期19-24,共6页 Infrared and Laser Engineering
关键词 衍射射透镜列阵 探测器 能量利用率 红外探测器 Diffraction microlens array Detector Energy utilization ratio Signal-noise ratio
  • 相关文献

参考文献2

共引文献1

同被引文献13

  • 1袁永刚,刘大福,邱惠国,李向阳.128×128元氮化镓紫外焦平面读出电路的设计与封装研究[J].红外与激光工程,2007,36(z1):93-96. 被引量:3
  • 2李向阳,许金通,汤英文,李雪,张燕,龚海梅,赵德刚,杨辉.GaN基紫外探测器及其研究进展[J].红外与激光工程,2006,35(3):276-280. 被引量:45
  • 3李毅.衍射微透镜阵列与紫外成像阵列单片集成技术:中国,200710040514[P].2008-11-12.
  • 4Ichiro Murakami, Takashi Nakano, Keisuke Hatano, et al. Technologies to improve photo-sensitivity and reduce VOD shutter voltage for CCD image sensors[J]. IEEE Transactions on Electron Devices, 2000,47(8):1566-1572.
  • 5M Edward Motamedi, William E Tennant, Haluk O Sankur, et al. Micro-optic integration with focal plane arrays[J]. Optical Engineering, 1997, 36(5):1374-1381.
  • 6Tsukamoto A,Kamisaka W,Senda H,et al. High sensitivity pixel technology for a 1/4-inch PAL 430K pixel IT-CCD[A]. Custom Integrated Circuits Conference, Proceedings of the IEEE 1996[C]. 1996.39-42.
  • 7Chen Sihai, Yi Xinjian, Li Yi, et al. Hybrid integration between long focus microlens array and IR detector array[J]. International J Infrared and Millimeter Waves, 2001,22(3): 393-398.
  • 8Yongqi Fu, Ngoi Kok Ann Bryan. Investigation of integrated diffractive/refractive microlens microfabricated by focused ion beam[J]. Review of Scientific Instruments, 2000,71(6):2263-2266.
  • 9杜春雷,郭履容,郭永康.菲涅耳型衍射光学元件的研究[J].光子学报,1997,26(9):824-831. 被引量:10
  • 10张玉虹,刘宝元.聚合物微透镜阵列的光学性能测试[J].中国西部科技,2008,7(27):14-16. 被引量:3

引证文献2

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部