期刊文献+

后路经寰枢关节螺钉固定术在儿童可行性的三维CT研究 被引量:1

The feasibility study of atlanto-axial transarticular fixation in children using multipanar reconstruction of helical computed tomography
原文传递
导出
摘要 目的了解影响儿童后路经寰枢关节螺钉安全置入的相关因素,提高手术的安全性。方法选取80名儿童的寰枢椎CT影像学资料,按年龄(Y)分为Y〈2岁组、2≤Y≤4岁组、4〈Y≤8岁组、8〈Y≤12岁组,每组各20名。三维重建后选取合适的轴性斜平面和双侧旁矢状斜平面,测量后路经寰枢关节螺钉固定的相关指标。结果(1)观察160侧所选取的旁矢状位斜平面CT影像,发现Ⅰ型椎动脉沟占76.25%、Ⅱ/型占6.25%、Ⅲ型占12.5%、Ⅳ型占5%。(2)不同年龄组间椎弓峡部宽度和高度有统计学意义(P〈0.05),理想螺钉路径到椎动脉的距离和置钉角度参数差异无统计学意义(P〉0.05)。(3)按设定标准1:椎弓峡部宽度、高度〉5mm,理想螺钉路径到椎动脉沟的距离〉2.5mm;标准2:椎弓峡部宽度、高度〉4.5mm,理想螺钉路径到椎动脉沟的距离〉2.5mm。Y〈2组儿童对于3.5mm螺钉一侧可置钉率分别为15%与40%;2≤Y≤4组为55%与85%;4〈Y≤8组为85%与95%;8〈Y≤12组为90%与90%。结论理想螺钉路径到椎动脉沟的距离能够更好地评估椎动脉沟变异对经寰枢关节螺钉固定术的影响。儿童进钉的合适内倾角和上倾角平均约为10°和40°。 Objective To investigate the factors that influence the appropriate placement of atlantoaxial transarticular screws in children. Methods 80 children were divided equally into 4 groups by the age (Y): Y〈2, 2≤Y≤4, 4〈Y≤8 and 8〈Y≤ 12 respectively, and the 3D CT images of cervical spines were captured and analysed. Some parameters were measured in the appropriate oblique axial planes and oblique parasagittal planes by using 3D reconstruction of the image on CT workstation. Results (1) In the oblique parasagittal CT images, Type Ⅰ vertebral artery groove contributed to 76.25%, type Ⅱ contributed to 6.25%, type Ⅲ contributed to 12.5%, and type Ⅳ contributed to 5%. (2) There were significant differences in the bilateral isthmus width and height within different groups. However, no significant differences were found for the distance between optimal screw path and artery groove, and the same result for angular parameters. (3) The first criterion was that both the isthmus width and height were greater than 5 mm, while the distance between optimal screw path and vertebral artery groove was greater than 2.5 mm. The second criterion was that both isthmus width and height were greater than 4.5 mm, while the distance between optimal screw path and artery groove was greater than 2.5 mm. The acceptance rates of 3.5mm screws on at least one side in group Y〈2 was 15% and 40% respectively according to criteria 1 and 2. The rates in group 2≤Y≤4 were 55% and 85%, were 85% and 95% in group 4〈Y ≤8, and were 90% and 90% in group 8〈Y ≤ 12. Conclusion The distance between optimal screw path and vertebral artery groove can provide a better evaluation than vertebral artery groove variation alone for atlantoaxial transarticular screws fixation. The average medial angle and sagittal angle are about 10°and 40°respectively, and that can be used as reference values.
出处 《中华骨科杂志》 CAS CSCD 北大核心 2008年第9期720-725,共6页 Chinese Journal of Orthopaedics
关键词 儿童 寰枢关节 骨螺丝 体层摄影术 螺旋计算机 Child Atlanto-axial joint Bone screws Tomography, spinal computed
  • 相关文献

参考文献16

  • 1Wang J, Vokshoor A, Kim S, et al. Pediatric atlantoaxial instability:management with screw fixation. Pediatr Neurosurg, 1999, 30: 70- 78.
  • 2Brockmeyer DL, York JE, Apfelbaum RI. Anatomical suitability of C1-2 transarticular screw placement in pediatric patients. J Neurosurg, 2000, 92(1 Suppl): 7-11.
  • 3Nogueira-Barbosa MH, Defino HL. Muhiplanar reconstructions of helical computed tomography in planning of atlanto-axial transarticular fixation. Eur Spine J, 2005, 14: 493-500.
  • 4Paramore CG, Dickman CA, Sonntag VK. The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg, 1996, 85: 221-224.
  • 5Meyer B, Vieweg U, Rao JG, et al. Surgery for upper cervical spine instabilities in children. Acta Neurochir (Wien), 2001, 143: 759- 765.
  • 6Gluf WM, Brockmeyer DL. Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients. J Neurosurg Spine, 2005, 2: 164-169.
  • 7Mandel IM, Kambach BJ, Petersilge CA, et al. Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws. Spine, 2000, 25: 1542-1547.
  • 8曹正霖,钟世镇,徐达传.寰枢椎的解剖学测量及其临床意义[J].中国临床解剖学杂志,2000,18(4):299-301. 被引量:138
  • 9瞿东滨,钟世镇,徐达传.枢椎椎弓根及其内固定的临床应用解剖[J].中国临床解剖学杂志,1999,17(2):153-154. 被引量:84
  • 10Karaikovic EE, Daubs MD, Madsen RW, et al. Morphologic characteristics of human cervical pedicles. Spine, 1997, 22: 493-500.

二级参考文献20

  • 1高雨仁,杨桂姣,阎八一,马迅,马景昆,张建中.颈椎后路关节突-椎弓根联合内固定的解剖学基础[J].解剖学杂志,1994,17(6):477-480. 被引量:14
  • 2章庆峻.上颈椎不稳外科治疗的进展[J].中国矫形外科杂志,1996,3(3):212-214. 被引量:7
  • 3Xu R M,Spine,1995年,20卷,3期,259页
  • 4Xu R,Spine,1995年,20卷,3期,259页
  • 5Madawi AA,Casey TH,Solanki GA,et al.Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique[].Journal of Neurosurgery.1997
  • 6Dickman CA,Sonntag VKH.Posterior C1 ~C2 transarticular screw fixation for atlantoaxial arthrodesis[].Neurosurgery.1998
  • 7Grob D,Jeanneret B,Aebi M,et al.Atlanto- axial fusion with transarticular screw fixatiom[].Journal of Bone and Joint Surgery British Volume.1991
  • 8Stillerman CB,Wilson JA.Atlanto-axial stabilization with posterior transarticular screw fixation: Technical description and report of 22 case[].Neurosurgery.1993
  • 9Marcotte P,Dickman CA,Sonntag VKH,et al.Posterior atlantoaxial facet screw fixation〔J〕[].Neurosurgery.
  • 10Paramore CG,Dickman CA,Sonntag VKH.The anatomical suitability of the C1~2 complex for transarticular screw fixatior[].Journal of Neurosurgery.1996

共引文献225

同被引文献13

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部