摘要 分析了用电负荷管理无线通信系统雷害的可能途径以及周围环境对防雷的影响。采用IEC方法对该系统进行了综合雷害风险评估,评估结果与系统已有运行经验基本吻合。针对天线部分的具体特点,将天线部分作为雷害风险评估重点,并分析了该系统防雷的技术经济性。 The possible ways of the lightning stroke damages of the wireless communication system for electric power load managment and the surroundings influence for lightning protection were analyzed..The IEC' s approach was applied to assess all damages produced by lightning. The assessment results were in accordance with the operating experience. According to the characteristics of antenna, the antenna was taken as the key of lightning damage risk assessment. The economy performance of lightning protection technology was also analyzed.
出处 《低压电器》 北大核心 2008年第16期42-46,共5页 Low Voltage Apparatus
关键词 用电负荷管理 无线通信系统 雷害 风险评估 management of electric power load wireless communication system lightning damages risk assessment
  • 相关文献

参考文献7

  • 1IEC 62305-2 Protection Against Lightning Part2: Risk Management[ S].
  • 2ITU-K39 Risk Assessment of Damages to Telecommunication Sites Due to Lightning Discharges[ S].
  • 3WU Guifang, WEN Xishan, CHAI Xuzheng. Assessment of the Risk of Damage Due to Lightning in the Information System [ J]. 3rd International Symposium on Electromagnetic Compatibility, 2002:299-303.
  • 4IEC 61312-2 Protection Against Lightning Electromagnetic Impulse (LEMP) [S].
  • 5GB50343-2004.建筑物电子信息系统防雷技术规范[S].[S].,..
  • 6GB 50057-1994(2000) 建筑物设计防雷规范[S].
  • 7GB50058-1992,爆炸和火灾危险环境电力装置设计规范[S]