摘要
在6.0mol/LHCI介质中,用乙酸丁酯苹取镓,水反革取后,用火焰原子吸收测定镓。方法线性范围为0~100μg/mL,检出限为0.028μg/mL,样品加标回收率为97.9%~101.8%,RSD在2.83%~3.96%之间。方法应用于拜尔溶液中镓的测定,结果满意。
Using butyl acetate to extract Ga in 6.0mol/L HCI medium, Ga will be determinated by using flame atomic absorption after water reextracting. The method has a linear range for Ga as 0~100μg/mL with the detection limit being 0. 028μg/mL. The recoveries of standard addition are in the range of 97. 9~101.8% with RSDs between 2.83% and 3. 96%. Satisfactory results have been achieved by applying this method to determinating Ga in Bayer solution.
出处
《矿产与地质》
2008年第3期277-279,共3页
Mineral Resources and Geology
基金
广西地质勘查专项经费项目(020210)资助
关键词
镓
火焰原子吸收光谱法
铝酸钠溶液
Ga, flame atomic absorption spectrometry, sodium aluminate solution