摘要
本法较准确,精密度好。在4N HCl介质中铀被TNOA萃取后,又用0.2NHNO_3反萃取。反萃取液不需用高氯酸蒸干。随后用铜铁试剂催化极谱法测定铀。进行了分离条件研究。分析结果与标样数值相符合。
Uranium (Ⅵ) is separated by TNOA extraction in 4N HCl. Then it is back-extracted with 0.2 N nitric acid and determined with cupferron catalytic polarographic method. There is no need to evaporate back-extract with perchloric acid. Results were in good agreement with certified values of standard reference materials. This method is more accurate and precise.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
1989年第2期177-179,共3页
Chinese Journal of Analytical Chemistry