通过对哈市松北地区10 kV配电网中电容电流的分析,阐述了消弧线圈在松北区配电网中应用的必要性,并对消弧线圈、接地变压器的工作原理、容量选择等方面进行了说明。
The paper discussed the necessity applied arc -suppression coil to Songbei district distribution grid by analyzing the capacitance current in 10 kV distribution in Harbin songbei district, and introduced to themechanism of arc - suppression coil and earthed transformer and selection of their capacity.