期刊文献+

Data processing in pulse transit time measurement

Data processing in pulse transit time measurement
下载PDF
导出
摘要 PuLse transit time(FIT)is used as a noninvasive and cull-less parameter to estimate blood pressure.In this paper,we develop an algorithm to obtain FTT rapidly,which is appropriate for micro-processor and could achieve good accuracy in PTT,even in noisy measurements.The algorithm is based on finite impulse response(FIR)filter to reduce the noise and an adaptive threshold to detect the significant points of ECG and PPG.Evaluation of this method is based on the signals from our PTr-based blood pressure devices.It is shown that the method works well for PPT calculation. Pulse transit time (PTT) is used as a noninvasive and cuff-less parameter to estimate blood pressure. In this paper, we develop an algorithm to obtain PTT rapidly, which is appropriate for micro-processor and could achieve good accuracy in PTT, even in noisy measurements. The algorithm is based on finite impulse response (FIR) filter to reduce the noise and an adaptive threshold to detect the significant points of ECG and PPG. Evaluation of this method is based on the signals from our PTT-based blood pressure devices. It is shown that the method works well for PPT calculation.
出处 《生命科学仪器》 2008年第8期18-21,共4页 Life Science Instruments
关键词 脉冲技术 测量方法 数据处理 转换时间 pulse transit time data process PPG ECG
  • 相关文献

参考文献9

  • 1A. Johansson,C. Ahlstrom,T. Lanne,P. Ask.Pulse wave transit time for monitoring respiration rate[J].Medical & Biological Engineering & Computing.2006(6)
  • 2X.F.Teng,Y.T.Zhang."An evaluation of a PTT-Based Method for Noninvasive and Cuff-less Estimation of Arterial Blood Pressure"[].Proceedings of the th IEEE EMBS Annual International Conference.2006
  • 3A.Johansson,C.Ahlstrom,T.Lanne,P.Ask."Pulse wave transit time for monitoring respiration rate"[].Medical and Biological Engineering and Computing.2006
  • 4C.C.Y.Poon,Y.T.Zhang."Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time"[].ProeOf the th AnnConfof IEEE-EMBC.2005
  • 5Javier Espina,Thomas Falck,Jens Muehlsteff,Yilin Jin,Miguel A Adan,Xavier Aubert."Wearable body sensor network towards continuous cuff-less blood pressure monitoring"[].The BSN /ISSS-MDBS.2008
  • 6J.Pan,W.J.Tompkins."A Real-Time ORS Detection Algorithm"[].IEEE Transactions on Biomedical Engineering.1985
  • 7J.M.Zhang,,P.F.Wei,,Y.Li."A LabVIEW based mea- surement system for pulse wave transit time"[].ITABOS.2008
  • 8Alan V.Oppenheim,Alan S.Willsky,S.Hamid Nawab.Signals and Systems[]..
  • 9Fei Zhang,Ying Wei,Yong Lian."Efficient QRS detec- tion in wearable ECG devices for body sensor network"[].The BSN /ISSS-MDBS.2008

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部