期刊文献+

三种全瓷冠的临床效果观察 被引量:3

下载PDF
导出
摘要 目的总结应用3种陶瓷全瓷冠的临床效果,为全瓷冠的材料选择应用提供参考。方法选择门诊患者90例,采用IPS Empress热压铸造陶瓷、In-ceram渗透陶瓷以及Cerec2 CAD/CAM技术制作前牙全瓷冠各30件,临床定期观察。结果修复体咀嚼功能好,美观,适合性好,无食物嵌塞,无继发龋及龈炎。Cerec Vita MarkⅡ全瓷冠有1件冠折裂,2件出现裂纹;IPS EmpressⅡ全瓷冠有2件出现裂纹,未折裂;In-Ceram全瓷冠未出现裂纹、折裂现象。结论In-Ceram全瓷冠临床应用效果好。
出处 《广东牙病防治》 2008年第B07期593-594,共2页 Journal of Dental Prevention and Treatment
  • 相关文献

参考文献9

  • 1YOSHINARI M, DERAND T. Fracture strength of all-ceramic crouns. Int J Prosthodont, 1994,7(4) :329-338.
  • 2PETERS M C, DE VREE J H, BREKETMANS W A. Distributed crack analysis of ceramic inlays. J Dent Res, 1993,72( 11 ) :1537- 1542.
  • 3LIU P R. A Panorama of dental CAD/CAM restorative systems. Conpend Contin Educ Dent, 2005,26(7) :507-516.
  • 4CAMPBELL S D, PELLETIER L, POBER R L, et al. Dimensional and fomation analysis of a restorative ceramic and how it works. J Prosthet Dent, 1995,74(4) :332-340.
  • 5PROBSTER L. Compressive strength of two mobern all-ceramic crowns. Int J Porsthodont, 1992,5 ( 5 ) :409-414.
  • 6RINKE S, HULS A, JAHN L. Marginal accuracy and fracture strength of coventional and copy-milled all-ceramiccrowns. Int J Prosthodont, 1995,8(4) :303-310.
  • 7BESCHNIDT S M, STRUB J R. Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth. J Oral Rehabil, 1999,26(7) :582-593.
  • 8SHEARER B, GOUGH M B, SETCHELL D J. Influence of marginal configuration and porcelain addition on the fit of In-Ceram crowns. Biomaterials, 1996,17 ( 19 ) : 1891-1895.
  • 9邓斌,刘洪臣,温宁,张少锋.三种牙科全瓷底层材料饰瓷后相对透明率的对比测定[J].北京口腔医学,2005,13(1):23-25. 被引量:12

二级参考文献7

  • 1Crispin BJ, Okamoto SK, Globe H. Effect of porcelain crown substructures on visually perceivable value.J Prosthet Dent, 1991,66(2):209-212.
  • 2Kelly JR, Nishimura I, Campbell SD. Ceramics in dentistry: historical roots and current perspectives.J Prosthet Dent, 1996,75(1):18-32.
  • 3Heffernan MJ,Aquilino SA,Diaz-Arnold AM,et al. Relative translucency of six all-ceramic systems. Part I: core materials.J Prosthet Dent,2002,88(1):4-9.
  • 4Lund PS,Campbell SD,Giordano RA.Translucency of core and veneer material for all-ceramic crowns.J Dent Res,1996,75:285.
  • 5Nagai SJ,Furukawa K,Ishibashi K,et al.Optical evaluation of the translucency of In-Ceram core material.J Dent Res,1996,75:248.
  • 6Heffernan MJ,Aquilino SA,Diaz-Arnold AM,et al.Relative translucency of six all-ceramic systems. Part II:core and veneer material. J Prosthet Dent,2002,88(1):10-15.
  • 7Reich S,Hornberger H.The effect of multicolored machinable ceramics on the esthetics of all-ceramic crowns.J Prosthet Dent,2002,88(1):44-49.

共引文献11

同被引文献15

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;