摘要 基于超声的组织损伤无损检测在HIFU临床的推广与应用中具有重要意义。提出一种基于相关距离的快速算法,通过对辐照前后HIFU焦域位置超声图像进行二维亚像素级互相关分析,追踪超声图像的中特征点的位移及变化,从而对HIFU焦域位置生物组织的细微热损伤进行检测。结果表明,超声图像亚像素级相关分析矢量场可反映组织发生凝固性坏死的位置,其相关距离可以辅助探测组织束损伤程度。 Ultrasound based tissue thermal lesion non-invasive detection has an important significance in HIFU clinic application. We proposed a fast correlation-distance based method, which analyses the sub-pixel level cross-correlation of ROI(region of interest) of ultrasound images before and after HIFU exposure. Detection of tiny thermal lesion of tissue is performed by tracing the movement and change of featured points on ultrasound images. The results showed that sub-pixel cross-correlation vector field can reflect the ablation lesions position and correlation distance is helpful for detecting the degree of the beam ablation lesions.
出处 《传感技术学报》 CAS CSCD 北大核心 2008年第8期1319-1324,共6页 Chinese Journal of Sensors and Actuators
基金 863国家重点项目资助(2007AA022000)
关键词 图像变化探测 无损检测 亚像素 组织热损伤 image change detection non-invasive detection sub-pixel tissue thermal lesion
  • 相关文献

参考文献15

  • 1范良志,罗飞,喻道远,刘夏天,张静,谢明星.高强度聚焦超声肿瘤治疗机开发中的关键技术[J].中国医疗器械杂志,2005,29(2):115-119. 被引量:9
  • 2李勤 陈健 桂永忠 等.高强度聚焦超声治疗肝癌的影像学观察.中华超声影像学杂志,2000,9(10):595-595.
  • 3邹建中,伍烽,陈文直,彭剑萍,朱辉,李佩希,廖翠蓉,曹玲,张欲晓,谢昭鹏,白晋,王芷龙,王智彪.高强度聚焦超声治疗164例恶性肿瘤的声像图监测及变化[J].中华超声影像学杂志,2000,9(12):739-741. 被引量:30
  • 4Clarke RL, Bush NL, Terhaar GR. The Changes in Acoustic Attenuation Due to in Vitro Heating[J]. Ultrasound in Med & Biol, 2003,29(1):127-135.
  • 5Zderic V, Keshavarzi A, Andrew MA, et al. Attenuation of Porcine Tissues in Vivo after High Intensity Ultrasound Treatment[J]. Ultrasound in Med & Biol, 2004, 30(1) : 61-66.
  • 6Bevan PD, Sherar MD. B-scan Ultrasound Imaging of Thermal Coagulation in Bovine Liver: Log Envelope Slope Attenuation Mapping[J], Ultrasound in Med & Biol, 2001,27(3) : 379-387.
  • 7Bevan PD, Sherar MD.B-Scan Ultrasound Imaging of Thermal Coagulation in Bovine Liver: Frequency Shift Attenuation Mapping[J]. Ultrasound in Med & Biol, 2001,27 (6) : 809- 817.
  • 8Stafford R J, Kallel F, Price RE, et al. Elastographic Imaging of Thermal Lesions in Soft tissue: a Preliminary Study in Vitro [J]. Ultrasound in Med & Biol, 1998,24 (9) : 1449-1458.
  • 9Kallel F, Stafford RJ, Price Elastographic Visualization of RE, et al. The Feasibility of Hifu-Induced Thermal Lesions in Soft Tissues[J]. Ultrasound in Med & Biol, 1999, 25(4) 641-647.
  • 10Righetti R, Kallel F, Stafford P,J, et al. Elastographic Characterization of Hifu-Induced Lesions in Canine Livers[J]. Ultrasound in Med & Biol, 1999, 25(7):1099-1113.

二级参考文献16

  • 1上海交通大学 无锡海鹰电子医疗系统有限公司.高强度聚焦超声肿瘤冶疗用换能器阵列[P].中国专利公开号:CN1470299A..
  • 2北京源德生物医学工程股份有限公司.一种聚焦超声波波源[P].中国专利号:ZL01270265.X..
  • 3http://cimu.apl.washington.edu/hifusurgerysystem.html.
  • 4Focus Surgery Inc.,.Annular Array Transducer. US Patent No.,US5520188.
  • 5Chrsitian Bohris, et al. Qualitative MR Temperature Monitoring of High-Intensity Focused Ultrasound Therapy, Magnetic Resonance Imaging, 1999,17 (4): 603-610.
  • 6Sunnybrook Health Science Center. Imaging of Ultrasonic Fields with MRI,.US Patent No.: US6246895 B1.
  • 7Transurgical Inc. MRI-Guided Therapeutic Unit and Methods. US Patent No.:US6516211 B1.
  • 8Transurgical Inc. Interleaved Operation of MRI and Electronic Equipment. US Patent No.: US6501978 B2.
  • 9http://www.exablate2000.com/.
  • 10重庆海扶(HIFU)技术有限公司.高强度聚焦超声肿瘤扫描治疗系统[P].中国专利号:ZL98100283.8..

共引文献36

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部