期刊文献+

一个Bi系高温超导带样品的临界电流测定及稳定性实验研究

AN EXPERIMENTAL STUDY ON THE CRITICAL CURRENT MEASUREMENT AND STABILITY OF A Bi-BASE HIGH-Tc SUPERCONDUCTING TAPE SAMPLE
下载PDF
导出
摘要 就临界电流测定中地回路、样品电压信号引入检测仪表的极性、和样品放置不同状态经历不同时间对Bi系复银高温超导带材的临界电流、电压电流特性曲线形态、可逆性及稳定性的影响进行了实验研究。结果表明,电流不确定度为最大值的±05%。氧化物高温超导材料不宜在空气中保存。 An experimental study was made of the effect of the grounding loop, the polarity of the sample′s voltage to be injected into the test instrument, laying conditions and periods of the sample upon critical current, the shape of the voltagecurrent curves, reversibility and stability of a silversheathed, Bibased highTc superconducting tape sample. The experimental results showed that the current uncertainty is within ±05% of maximum current value. The oxide highTc superconducting tape can not be put in the air for keeping.
作者 陈继平
出处 《矿冶工程》 CAS CSCD 北大核心 1997年第4期66-68,共3页 Mining and Metallurgical Engineering
基金 国家超导研究与发展中心资助
关键词 临界电流 铋系超导带 超导材料 电流不确定度 Critical current measurement, Grounding loop, HighTc superconductors, Voltagecurrent characteristic, Current uncertainty