有源滤波器在谐波抑制中的应用 被引量:2

Application of Active Filter in Harmonics Father
下载PDF
导出
摘要 文章分析了谐波污染产生的原因,总结了抑制谐波的措施,重点分析了有源滤波器抑制谐波的原理及特点,最后通过对有源电力滤波器改善UPS电源谐波案例分析,阐明有源电力滤波器作为抑制谐波的装置,可以有效地抑制谐波,改善电网质量,具有广阔的应用前景。 The reason of harmonics pollution is analyzed in this passage, and the measures of restrain harmonics are provided, the principle and specialty of active power filter which restraining harmonics is analyzed stressly. At last,the passage analysis active power filter (AccuSine) applicated in reducing the UPS harmonics. It indicates that the active power filter is the effective device which can reduce the harmonics and improve the power quality. The future prospects of active power filter are presented.
作者 张坤
出处 《科技广场》 2008年第7期223-225,共3页 Science Mosaic
关键词 谐波 有源电力滤波器 Harmonics Active Power Filter
  • 相关文献

参考文献1

二级参考文献9

  • 1Akagi H, Kanazawa Y, Nabae A. Instantaneous reactive power compensators comprising devices without energy storage components[J]. IEEE Transactions on Industry Applications, 1984, 20(4):625-630.
  • 2Sasaki H, Machida T. A new method to eliminate AC harmonic current by magnetic compensation consideration on basic design[J]. IEEE Transactions on Power Apparatus and System, 1971,90(5): 2009-2019.
  • 3Akagi H, Fujita H. A new power line conditioner for harmonic compensation in power systems[J]. IEEE Transactions on Power Delivery, 1995, 10(3): 1570-1575.
  • 4Takeda M, Ikeda K, Tominaga Y et al. Harmonic compensation with active filter[C]. IEEE/IAS Annual Meeting, 1987: 808-815.
  • 5Peng F Z, Akagi H, Nabae A. A new approach to harmonic compensation in power systems--a combined system of shunt passive and series active filters[J]. IEEE Transactions on Industry Applications, 1990, 26(6): 983-990.
  • 6Fujita H, Akagi H. A practical approach to harmonic compensation in power systems--series connection of passive and active filters[J]. IEEE Transactions on Industry Applications, 1991, 27 (6):1020 -1025.
  • 7Chang W K, Grady W M, S amotyj M J. Controlling harmonic voltage and voltage distortion in a power system with multiple active power line conditioners[J]. IEEE Transactions on Power Delivery, 1995,10(3): 1670-1676.
  • 8Chang W K, Grady W M. Minimizing harmonic voltage distortion with multiple current-constrained active power line conditioners[J]. IEEE Transactions on Power Delivery, 1997, 12(2):837-845.
  • 9Yi H Y, Kwun C Y. Determination of location and sizes for active power line conditioners to reduce harmonics in power systems[J]. IEEE Transactions on Power Delivery, 1996, 11(3): 1610-1617.

共引文献147

同被引文献9

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部