摘要
目的:研究肥胖因素对全髋关节置换术中人工髋臼准确置入的影响。方法:选取来本院采用后外侧入路行全髋关节置换的55例患者,按体质量指数分为3组:正常体质量组(19例)、超重组(23例)及肥胖组(13例)。每例患者术后均拍摄骨盆正位片,测量髋臼杯前倾角、外展角。结果:术后正常体质量组、超重组和肥胖组患者的髋臼杯前倾角分别为11.0°±5.2°,11.6°±5.4°和10.4°±5.3°(F=0.368,P=0.665);外展角分别为43.4°±6.5°,45.3°±6.4°和43.1°±6.7°(F=1.274,P=0.335),差异均无统计学意义。结论:肥胖因素并不影响全髋关节置换术中人工髋臼的准确置入。
Aim: To research the influence of obesity factors on implantation of artificial acetabular in total hip replacement. Methods:Selected 55 patients underwent total hip replacement with posterolateral approach. Patients were divided into three groups ( healthy,n = 19; overweight,n =23; obese,n = 13) according to Body Mass Index (BMI) and acetabular cup angles were measured. Results.. The mean cup anteversion of three groups were 11.0°±5.2°,11.6°±5.4°104°±5.3° respectively, there were no differences among 3 groups ( P = 0. 665 ). Mean values for cup abduction angle of three groups were 43.4°±6.5°,45.3°±6.4°,43.1°±6.7° respectively, and there was no difference among 3 groups ( P = 0.335 ). Conclusion : Obesity does not influence the accuracy of cup implantion in total hip replacement.
出处
《郑州大学学报(医学版)》
CAS
北大核心
2008年第5期972-973,共2页
Journal of Zhengzhou University(Medical Sciences)
关键词
肥胖
关节置换术
髋臼
obesity
total hip replacement
acetabular