期刊文献+

肥胖对全髋关节置换术中人工髋臼准确置入的影响 被引量:2

In total hip replacement:obesity factors correlation with the accuracy of acetabular cup implantation
下载PDF
导出
摘要 目的:研究肥胖因素对全髋关节置换术中人工髋臼准确置入的影响。方法:选取来本院采用后外侧入路行全髋关节置换的55例患者,按体质量指数分为3组:正常体质量组(19例)、超重组(23例)及肥胖组(13例)。每例患者术后均拍摄骨盆正位片,测量髋臼杯前倾角、外展角。结果:术后正常体质量组、超重组和肥胖组患者的髋臼杯前倾角分别为11.0°±5.2°,11.6°±5.4°和10.4°±5.3°(F=0.368,P=0.665);外展角分别为43.4°±6.5°,45.3°±6.4°和43.1°±6.7°(F=1.274,P=0.335),差异均无统计学意义。结论:肥胖因素并不影响全髋关节置换术中人工髋臼的准确置入。 Aim: To research the influence of obesity factors on implantation of artificial acetabular in total hip replacement. Methods:Selected 55 patients underwent total hip replacement with posterolateral approach. Patients were divided into three groups ( healthy,n = 19; overweight,n =23; obese,n = 13) according to Body Mass Index (BMI) and acetabular cup angles were measured. Results.. The mean cup anteversion of three groups were 11.0°±5.2°,11.6°±5.4°104°±5.3° respectively, there were no differences among 3 groups ( P = 0. 665 ). Mean values for cup abduction angle of three groups were 43.4°±6.5°,45.3°±6.4°,43.1°±6.7° respectively, and there was no difference among 3 groups ( P = 0.335 ). Conclusion : Obesity does not influence the accuracy of cup implantion in total hip replacement.
出处 《郑州大学学报(医学版)》 CAS 北大核心 2008年第5期972-973,共2页 Journal of Zhengzhou University(Medical Sciences)
关键词 肥胖 关节置换术 髋臼 obesity total hip replacement acetabular
  • 相关文献

参考文献10

  • 1Sporer SM, Paprosky WG. Biologic fixation and bone ingrowth[ J]. Orthop Clin North Am ,2005,36( 1 ) :105
  • 2Fackler CD, Poss R. Dislocation in total hip arthroplastles [J]. Clin Orthop Relat Res,1980(151):169
  • 3Woo R, Morrey B. Dislocations after total hip arthroplasty [J]. J Bone Joint Surg Am, 1982,64(9):1295
  • 4Wolf A, DiGioia AM 3rd, Mor AB, et al. A kinematic model for calculating cup alignment error during total hip arthroplasty[ J]. J Biomech,2005,38( 11 ) :2257
  • 5Hassan DM, Johnston GH, Dust WN, et al. Accuracy of intra-operative assessment of acetabular prosthesis placement[J]. J Arthroplasty,1998,13(1):80
  • 6Jaramaz B, DiGioia AM 3rd, Blackwell M ,et al. Computer assisted measurement of cup placement in total hip replacement [ J ]. Clin Orthop Relat Res, 1998 ( 354 ) :70
  • 7Ezoe M, Naito M, Asayama I, et al. Pelvic motion during total hip arthroplasty with translateral and posterolateral approaches[ J]. J Orthop Sci,2005,10(2) :167
  • 8McCollum BJ,Gray WJ. Dislocation after total hip arthroplasty:Causes and prevention[J]. Clin Orthop Relat Res, 1990 (261) : 159
  • 9Obesity: preventing and managing the global epidemic:report of a World Health Organization Consultation of Obesity, Geneva, 1997 [ R ]. Geneva,World Health Organization, 1998.
  • 10Kummer F, Shah S, Iyer S,et al. The effect of acetabular cup orientations on limiting hip rotation[ J]. J Arthroplasty,1999,14(4) :509

同被引文献19

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部