摘要
本文介绍大气压离子质谱仪,用该法测定了高纯氨中的二氧化碳。叙述了共存水对二氧化碳测定的干扰及其用五氧化二磷的脱除方法。同时讨论了气体压力与二氧化碳含量的关系等。方法的测量精度优于10%。
In this paper, an Atmospheric Pressure Ionization Mass Spectrometer (API-MS) ispresented' API-MS method is studied for the determination of residual CO2 in high purity nitrogen. The interference of coexistent water with the CO2 and the method for removing the water by P2O5 trap are described. The influences of gas pressure on the CO2,concentration are discussed. The method precision is better than 10%.
出处
《质谱学报》
EI
CAS
CSCD
1997年第4期29-33,共5页
Journal of Chinese Mass Spectrometry Society
关键词
大气压离子质谱
高纯氮气
二氧化碳
APIMS, gas analysis, high purity nitrogen gas,CO_2,determination