摘要 提出了用离子色谱柱后衍生法同时测定汞和其它金属离子的新方法。本方法中样 品离子以阴离子交换分离,用2-(5-溴-2-吡啶偶氮)-5-二乙氨基酚(5-Br-PADAP)和非离子 表面活性剂 Triton X-100显色体系作柱后衍生,分光光度法测定。方法的检出限对 Hg2+、 Mn2+、Cd2+、Co2+、Zn2+、Ni2+和Cu2+分别为20、9、9、8、2、100和 3 μg/L。方法用于人头发样 品中微量汞的分析取得了满意结果。 A new method for simultaneous determination of mercury (Ⅱ) and some other metals by HPIC was established, which involves an on-column derivatisation with 2, 6-pyri- dine-dicarboxylic acid (PDCA ), an anion-exchange separation and a post-column chro- mogenic reaction with 2-[(5-bromo-2-pyridyl)-azo] phenol (5-Br-PADAP). The procedure was optimized with respect to the composition and pH of the eluent and the reagent. The detection limits for Cu2+, Ni2+, Zn2+, Co2+, Cd2+, Mn2+, and Hg2+ are 3, 100, 2, 8, 9, 9, 20 μg/L, respectively. The method has been applied to the determination of mercury in 300 mg human hair sample and the results obtained agree very well with the value announced.
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1997年第11期1241-1245,共5页 Chinese Journal of Analytical Chemistry
关键词 离子色谱法 柱后衍生 Ion chromatographic method, post-column derivatisation, mercury, manganese, cadmium, cobalt, zinc, nickel, copper
  • 相关文献

参考文献5

  • 1曹诗倜.一些有机分析试剂及其应用研究[J].分析科学学报,1996,12(2):168-174. 被引量:4
  • 2金伟,理化检验.化学分册,1995年,31卷,1期,53页
  • 3Wang Y C,J Chromatogr,1992年,628卷,133页
  • 4陈存之,理化检验.化学分册,1989年,25卷,1期,28页
  • 5牟世芬,离子色谱,1986年,150页

共引文献3

同被引文献224

引证文献5

二级引证文献44