摘要 利用自然排烟理论,根据理论计算参数,综合考虑建筑造型、使用安全等因素,对国家大剧院高大空间排烟系统进行分析与计算,得出采用自然排烟方法的各项技术参数。确定国家大剧院采用主壳体自然排烟与自然补风、机械补风、环廊机械排烟相结合的防排烟方案,确保了工程的使用安全。 By using the natural smoke extraction theory, based on the theoretical calculation parameter, and with a view to the architectural style, application safety and other factors, analyses and calculates the large space smoke extraction system of the theater, working out the technical parameters for natural smoke extraction. And determines adopting natural smoke extraction in the space of the main shell-body and mechanical smoke extraction in the annular corridor, with natural and mechanical smoke make-up, ensuring fire safety of the project.
作者 王旭 石鹤
出处 《暖通空调》 北大核心 2008年第9期52-54,共3页 Heating Ventilating & Air Conditioning
关键词 高大空间 机械排烟 自然排烟 补风 large space, mechanical smoke extraction, natural smoke extraction, air make-up
  • 相关文献

参考文献4

二级参考文献10

  • 1[1]Morgan H P, Hansell G O. Atrium buildings calculating smoke flows in atria for smoke control design. Fire Dafety Journal, 1987(12)
  • 2[2]Design approaches for smoke control in atrium buildings. Building Research Establishment 258
  • 3[4]Fire precautions in the design & construction of buildings BS 5588 Part2:1987(Formerly CP3: Chapter IV:Part 2)
  • 4SFPE engineering guide to performance-based fire protection analysis and design of buildings. Society of Fire Protection Engineers. Quincy, MA, First Ed, 2000.
  • 5John H Klote, James A Milke. Design of smoke management systems. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1791 Tullie Circle, N E Atlanta,GA 30329,1992.
  • 6NFPA 92B, Guide for smoke management systems in malls,atria, and large areas. Quincy, MA, 1995.
  • 7Morgan H P. Smoke control methods in enclosed shopping complexes of one or more storeys: a design summary. BRE,1979.
  • 8Morgan H P, Hansell G O. Fire sizes and sprinkler effectiveness in offices - implications for smoke control design.Fire Safety J, 1985,8(3) : 187 - 198.
  • 9Law M. Air supported structures: fire and smoke hazards. Fire Prevention, 1982,148.
  • 10NFPA 92A, Recommended practice for smoke-control systems.Quincy, MA, 1996.

共引文献14

同被引文献47

引证文献8

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部