摘要
根据1995年武汉地区实际气温,对常规温升变压器和温升限值降低5K的低温升变压器在额定负载下的平均相对老化率分别进行了计算,并对它们在高温日的寿命损失和负载能力进行了分析比较。
On the basis of the actual air temperatureof Wuhan District in 1995, the average relative ageing rates of two kinds of transformers operating at their rated load are calculated in this paper, the one having normal temperature-rise limit, the other having temperature-rise limit reduced by 5K.And their loss of life and loading capacity on the high air temperature days are also compared.
出处
《变压器》
北大核心
1997年第7期6-10,共5页
Transformer
关键词
变压器
寿命
温度
负载能力
Transformer, Life, Loading, Temperature rise, Analysis