北仑发电厂600MW机组振动波动的诊断与处理 被引量:5

Diagnosis and Treatment of Vibration of 600MW Unit in Beilun Power Plant
下载PDF
导出
摘要 对北仑发电厂二期工程#3汽轮发电机组的振动波动进行了测试,对数据进行了详细计算,结合振动趋势、振动频谱等进行分析,应用故障诊断原理判断其振动波动的原因为动静轻微摩擦,并结合经验认为,产生摩擦的原因是油挡处积炭引起,利用停机机会进行积炭处理后振动正常。 The vibration wave of the turbo-unit for the second-phase project in Beilun Power Plant was tested, and the data were calculated in details so that the slight rubbing was considered as the reason of a vibration wave by combining with analysis of vibration trend and vibration spectrum, and using the fault diagnosis. Based on our experience, it was thought that the reason of the rubbing was caused by carbon deposit in the oil catch, the vibration was normal after treating carbon deposit during the unit'shutdown.
作者 吴文健
出处 《热力透平》 2008年第3期201-203,187,共4页 Thermal Turbine
关键词 北仑发电厂 600MW 汽轮发电机组 振动 诊断 Beilun Power Plant 600MW turbo-unit vibration diagnosis
  • 相关文献

参考文献1

  • 1吴文健,张浩权,童小忠.大型汽轮发电机组密封瓦振动故障分析及处理[J].东南大学学报,2001,31(5A).

同被引文献28

引证文献5

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...