摘要
针对污水处理厂钢筋混凝土水池细部构造渗漏问题,进行了原因分析。指出施工不符合设计及规范要求,是主要原因。提出了工程施工中应采取的预防渗漏的技术措施。最后介绍了对已渗漏部位采用的治理措施。
To cope with the local leakage in the RC water tank structure in the sewage treatment works, an analysis is made of the cause therefor, indicating that the major cause is that construction is not in conformity with the requirements of design and specification. Engineering measures are proposed to prevent such leakage, and finally measures are taken against the leaking part of the structure.