摘要 透光特性是温室透光覆盖材料的一个重要指标,其数值的表达却因测试方法的不同而有所差异。该文介绍了透光覆盖材料太阳辐射透过率的测试及计算方法,选用聚乙烯塑料膜(PE)、浮法玻璃、聚碳酸酯双层中空板(PC)三种典型的覆盖材料进行了测试,计算了国际照明委员会(CIE)规定的标准C、标准A和标准D65三种光源下,在可见光与PAR波段范围内,基于4种权重系数下的覆盖材料透光率和光合有效辐射(PAR)透过率。结果表明,PE薄膜几乎不受影响,浮法玻璃相差2%左右,聚碳酸酯双层中空板差异达2%~3.7%。 Solar visible transmittance is crucial for greenhouse glazing. Different test methods for solar visible transmittance of glazing induce different results. The present paper described test and calculating methods for solar transmittance of glazing. Three typical glazing materials, namely, polyethylene(PE) film, float glass and double polycarbonate(PC) sheet, were measured and calculated under different International Commission on Illumination(CIE) standard sources(A, C and D65), within the visible and photosynthetic active radiation(PAR) spectra, using four response coefficients to solar radiation. Results show that PE film is not affected and float glass differs 2%, the difference of double polycarbonate sheets is up to 2%-3.7%.
出处 《农业工程学报》 EI CAS CSCD 北大核心 2008年第8期210-213,共4页 Transactions of the Chinese Society of Agricultural Engineering
基金 国家"十一五"科技支撑计划重点项目"现代高效设施农业工程技术研究与示范"(2006BAD28B07) 863计划:基于环境模拟的日光温室结构优化与数字化设计(2006AA10Z260)
关键词 温室覆盖材料 透光率 可见光 PAR 测试方法 greenhouse glazing light transmittance visible radiation PAR test method
  • 相关文献

参考文献23

  • 1GB4455-2006,农业用聚乙烯吹塑棚膜[S].
  • 2GB/T20202-2006,农业用乙烯-乙酸乙烯酯共聚物(EVA)吹塑棚膜[S].
  • 3GB 11614-1999,浮法玻璃[S].
  • 4NY/T1362-2007,温室用聚碳酸酯中空板[S].
  • 5JG/T116-1999,聚碳酸酯(PC)中空板[S].
  • 6JB/T10286-2001,日光温室结构[S].
  • 7NYJ/T05.2005,目光温室建设标准[S].
  • 8JB/T10288-2001,连栋温室结构[S].
  • 9NYJ/T06-2005,连栋温室建设标准[S].
  • 10ASAE EP460 FEB04, Commercial Greenhouse Design and Layout[S].

二级参考文献14

  • 1曹楠,林聪,王宇欣,黄之栋,王小玲,王金花.PETP薄膜保温特性的试验研究初报[J].农业工程学报,2004,20(4):242-245. 被引量:6
  • 2邹志荣.设施园艺学[M].北京:中国农业出版社,2002..
  • 3GB/T 2410-1980,透明塑料透光率和雾度试验方法[S].
  • 4GB/T 2680-1994,建筑玻璃可见光透射比、太阳光直接透射比、太阳能总透射比、紫外线透射比及有关窗玻璃参数的测定[S].
  • 5ISO9050-2003,Glass in building-determination of light transmittance,solar direct transmittance,total solar energy transmittance,ultraviolet transmittance and related glazing factors[S].
  • 6张福墁.设施栽培学[M].北京:中国农业大学出版社,2001.
  • 7穆天明.保护地设施学[M].北京:中国林业出版社,2004.
  • 8美国温室制造业协会.温室设计标准[M].周长吉,程勤阳译.北京:中国农业出版社,1998.
  • 9Langhans R W,Tibbitts T W.Plant growth chamber handbook[M].Iowa:North Center Regional Research Publication,1997.
  • 10王高伟,贺冬仙.温室覆盖材料的分光特性监测与评价[A].都市农业工程科技创新与发展[C].北京:中国水利水电出版社,2005:275-284.