期刊文献+

椭圆中心对比增强MPA在颈动脉狭窄诊断中的应用

下载PDF
导出
摘要 目的:研究椭圆中心(elliptical-centric)对比增强磁共振血管成像(contrast enhanced magnetic resonance angiography,CE-MRA)在颈动脉狭窄诊断中的应用价值,探讨椭圆中心CE-MRA的优势。方法对2005年11月至2007年3月期间44例临床疑有颈动脉狭窄的患者行椭圆中心CE-MRA检查,其中26例患者行DSA检查。26例可评价病例以DSA作为金标准进行对照。结果44例患者椭圆中心CE-MRA均满意地显示了颈部动脉血管节段。26例椭圆中心CE-MRA共观察52条血管节段,显示可比动脉节段32条,与DSA比较,对狭窄程度诊断的符合率为87.5%(28/32),与DSA结果进行一致性检验,计算Kappa值为0.92,具有很好的一致性:椭圆中心CE-MPA诊断狭窄的敏感度为100%(30/30),特异度为90.9%(15/17),阳性预测值为93.8%(30/32),阴性预测值为100%(20/20)结论椭圆中心CE-MRA与DSA比较,具有很好的一次性,能较准确地评价颈动脉狭窄,是一种有价值的、可靠的、无创的检查方法。
出处 《新疆医学》 2008年第8期1-3,共3页 Xinjiang Medical Journal
  • 相关文献

参考文献12

  • 1Thompson JE. Evolution of stroke surgery. Stroke, 1996,27 : 1427 - 1434.
  • 2Esrol GJ. Fisher and the history of carotid artery desease. Stroke, 1996,27:559 -560.
  • 3Earnest F, Forbes G, Sandok BA, et al. Complications of cerebral angiography: prospective assessment of risk. AJR, 1984,142:247 - 253.
  • 4Den JA,Hoogeveen R. Conlrast enhanced MR angiography Medica Mundi ,2001,45( 1 ):10--22.
  • 5Maki JH, Prince MR, Londy FJ, et al. The effect of time varying intravascular signal intensity and K -space acquisition order on three -dimensional MR angiography image quality. J Magn Resort hnaging. 1996.6(4) :642 -651.
  • 6张兆琪,吕飙,马晓海,范占明,赵轶柯,晏子旭.对比增强磁共振血管成像诊断先天性主动脉弓部畸形[J].中国医学影像技术,2003,19(10):1310-1313. 被引量:10
  • 7张兆琪,马晓海,晏子旭,赵轶柯,范占明,吕飙,贺毅.对比增强磁共振冠状动脉成像的初步研究[J].中国医学影像技术,2003,19(10):1306-1309. 被引量:10
  • 8Prince MR, Narasimham DL, Stanley JC, et al. Breath - hold gadolinium - enhanced MR angiography of the abdominal aorta and its major branches Radiology, 1995,197:785 - 792.
  • 9宋金松,刘玉清,朱杰敏,俞肖一,凌坚,严洪珍,蒋世良.三维增强磁共振血管造影(60例临床应用分析)[J].中华放射学杂志,1999,33(9):602-605. 被引量:41
  • 10Hany TF, Debatian JF, Leung DA, et al. Optimization of contrast timing for Breath - hold three - dimensional MR angiography. Radiology, 1997,204 : 357 - 362.

二级参考文献24

  • 1Lorenz CH, Johansson L. Invited: Contrast-enhanced coronary MRA[J]. J Magn Reson Imaging, 1999,10(5) :703-708.
  • 2Maki JH, Chenevert TL, Prince MR, et al. Contrast-enhanced MR angiography[J]. Applied Radiology Supplement, 2000, 3 (1) :5-20.
  • 3Deshpande VS, Wielopolski PA, Shea SM, et al. Coronary artery imaging using contrast-enhanced 3D segmented EPI [J]. J Magn Reson Imaging, 2001,13(5):676-681.
  • 4Kessler W, Laub G, Achenbach S, et al. Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breathhold imaging-initial experience[J].Radiology, 1999, 210 (2) : 566-572.
  • 5Duerinckx AJ. Coronary MR angiography[J]. Radio Clin North Am, 1999,37(2) : 273-318.
  • 6Nikolaou K, Huber A, Becker C, et al. Intraindividual comparison of contrast-enhanced electron-beam computed tomography and navigator-echo-gated-based magnetic resonance imaging for noninvasive coronary artery angiography[J]. Eur Radiol, 2002, 12 (7):1663-1671.
  • 7Zheng J, Li D, Bae KT, et al. Three-dimensional gadolinium-enhanced coronary MR angiography: Initial experience[J]. J Cardiovasc Magn Reson, 1999, 1(1) :33-42.
  • 8Li D, Zheng J, Weinmann HJ. Contrast-enhanced MR imaging of coronary arteries: Comparison of intra- and extravascular contrast agents in swine[J]. Radiology, 2001,218(3) :670-678.
  • 9Taupitz M, Schnorr J, Wagner S, et al. Coronary MR angiography: Experimental results with a monomer-stabilized blood pool contrast medium[J]. Radiology, 2002,222(1) : 120-126.
  • 10Martin RP, Thomas MG, Jorg FD, et al. 3D Contrast MR Angiography[M]. 2nd ed. New York: Springer, Berlin, Heidelberg,1999.

共引文献65