摘要
研究拟定了一种快速测定催化剂中钯的分析方法。该方法采用微波封闭溶样,在pH值为3.3乙酸介质中,选用工业品洗洁精为增溶、增敏试剂,以硫代米蚩酮分光光度法直接进行测定。该方法的测定范围为(0.5~xx)×10^-6,RSD为4.8%。经样品验证,结果令人满意。
A fast measurement method for palladium in activator is planned. With microwave sealed sample dissolution process and pH = 3.3 acetic acid media, sulfo-Michler's ketone spectrophotometric method is used directly in measurement with industrial liquefied detergent as solubilization and sensitizing agent. The measurement range of the method is(0.5 -xx) × 10^-6, and RSD is 4.8%. Good results are achieved.
出处
《黄金》
CAS
北大核心
2008年第9期48-49,共2页
Gold
关键词
微波溶样
硫代米蚩酮光度法
钯
催化剂
sealed dissolution
sulfo-Michler's ketone spectrophotometric method
palladium
activator