为探索在确保湿法脱硫机组高效稳定运行的同时有效降低耗电量,实现节能与减排双赢,对望亭发电厂300 MW燃煤机组脱硫系统运行方式进行分析、试验,通过优化脱硫设备运行方式和加强检修维护等手段,在保证脱硫效率、投运率的前提下,有效地降低了脱硫系统耗电量,取得了良好成效,对同类型发电企业具有很好的借鉴意义。
To explore methods for effectively reducing electricity consumption of the wet flue gas desulphurization system while ensuring its high-efficient and stable operation to realize energy-saving and emission-reducing at the same time, the operational mode of the desulphurization system for a 300 MW coal-fired unit of Wangting Power Plant is studied. The approaches to realize above targets are recommended, such as optimizing the operational mode of the desulphurization equipment and enhancing its maintenance.
出处
《华东电力》
北大核心
2008年第8期115-118,共4页
East China Electric Power
关键词
燃煤机组
湿法脱硫
运行优化
检修维护
降耗
coal-fired unit
wet flue gas desulphurization
operation optimization
maintenance
consumption reduction