期刊文献+

微创LISS接骨板治疗胫骨近端粉碎骨折 被引量:1

下载PDF
导出
摘要 目的观察LISS接骨板微创内固定治疗胫骨近端粉碎骨折的效果。方法分析17例住院胫骨近端粉碎骨折应用LISS接骨板治疗患者的资料。结果随访7-19个月,16例骨折均在6个月内愈合,1例Ⅱ期植骨第6个月愈合。结论LISS接骨板对胫骨近端粉碎骨折是一种有效的微创内固定。
作者 方志峰
出处 《现代中西医结合杂志》 CAS 2008年第29期4580-4581,共2页 Modern Journal of Integrated Traditional Chinese and Western Medicine
  • 相关文献

参考文献6

  • 1罗从风,陈云丰,高洪,杨发民,眭述平,曾炳芳.改良双钢板法治疗复杂胫骨平台骨折[J].中华骨科杂志,2004,24(6):326-329. 被引量:299
  • 2Sirkin MS, Bono CM, Reilly MC, et al. Percutaneous methods of tibial plateau fixation[J]. Clin Orthop,2000(375) :60-68
  • 3Zlowodzki M, Willianson S, Cole PA, et al. Biomechanical evaluation of the less invasive stabilization system, angled bladeplate, and retrograde intramedullary nail for the internal fixation of distal femur fracture[J]. J Orthop Trauma,2004,18(8) :494 - 502
  • 4Frigg R, Appenzeller A, Christensen R, et al. The development of the distal femur Less Invasive Stabilization System(LISS)[J]. Injury,2001,32(3 Suppl) :24 - 31
  • 5罗从风,姜锐,曾炳芳.应用微创内固定系统治疗胫骨近端骨折[J].中华创伤骨科杂志,2005,7(12):1124-1127. 被引量:41
  • 6刘璠,唐亮,茹江英,张驰.微创内固定系统治疗膝关节周围骨折[J].中华创伤骨科杂志,2006,8(10):949-953. 被引量:13

二级参考文献34

  • 1罗从风,陈云丰,高洪,杨发民,眭述平,曾炳芳.改良双钢板法治疗复杂胫骨平台骨折[J].中华骨科杂志,2004,24(6):326-329. 被引量:299
  • 2刘璠,茹江英,顾永强,严勋,施红光,王友华,曹毅,赵剑,陈向东,朱鸣镝,祝勇,王洪,曹涌.微创内固定系统治疗复杂性膝关节周围骨折的近期疗效[J].中华创伤骨科杂志,2005,7(11):1015-1020. 被引量:50
  • 3Marsh JL,Smith ST,Do TT.External fixation and limited internal fixation for complex fractures of the tibial plateau.J Bone Joint Surg(Am),1995,77:661-673.
  • 4Siliski JM,Mahring M,Hofer HP.Supracondylar-intercondylar fractures of the femur.Treatment by internal fixation.J Bone Joint Surg(Am),1989,71:95-104.
  • 5Bolhofner BR.Indirect reduction and composite fixation of extraarticular proximal tibial fractures.Clin Orthop,1995,(315):75-83.
  • 6Ries MD,Meinhard BP.Medical external fixation with lateral plate internal fixation in metaphyseal tibia fractures.A report of eight cases associated with severe soft-tissue injury.Clin Orthop,1990,(256):215-223.
  • 7Weiner LS,Kelley M,Yang E,et al.The use of combination internal fixation and hybrid external fixation in severe proximal tibia fractures.J Orthop Trauma,1995,9:244-250.
  • 8Hutson JJ,Zych GA.Infections in periarticular fractures of the lower extremity treated with tensioned wire hybrid fixators.J Orthop Trauma,1998,12:214-218.
  • 9Kumar A,Whittle AP.Treatment of complex (Schazker type Ⅵ) fracture of the tibial plateau with circular wire external fixation:retrospective case review.J Orthop Trauma,2000,14:339-344.
  • 10Watson JT.High-energy fractures of the tibial plateau.Orthop Clin North Am,1994,25:723-752.