摘要
针对某电厂DG260/9.81-3型燃烧煤矸石循环流化床锅炉启动和运行中出现的问题进行了仔细的分析,经过技术改造和运行调整后,提高了锅炉运行的安全性和稳定性给出了改造措施。
A careful analysis is carried out in this paper on the problems encountered in the starting and operation of the type DG260/9.81- 3 waste coal burning circulating fluidized bed boiler. The paper indicates that after technical upgrading and operation adjustment the safety features and the operation stability of this boiler is improved. This result is of signifieance to the operation of the coal burning circulating fluidized bed boils of the same type.
出处
《中国煤炭》
北大核心
2008年第9期89-91,共3页
China Coal
关键词
流化床锅炉
煤矸石
冷渣器
漏灰
fluidized bed boiler, waste coal, combustion, slag leakage