摘要
滨海电厂护岸防浪墙顶高程的合理确定,对于电厂的安全运行至关重要。由不同规程规范确定的滨海电厂厂区护岸防浪墙顶高程相差较大,通过广西防城港电厂护岸防浪墙顶标高的确定,探讨海滨电厂合理护岸防浪墙顶高程的确定方法。
It is of great importance to properly determine the top elevation of the revetment and seawall for the safe operation of the seaside power plant. The top elevations of revetment and seawall determined according to different codes and standards are quite different from each other, this article discusses the reasonable ways to determine the top elevation of the revetment and seawall by the determination of that for the Fangehenggang power plant in Guangxi province.
出处
《山东电力技术》
2008年第5期63-66,共4页
Shandong Electric Power
关键词
电厂
护岸
防浪墙
顶标高
确定
power plant
revetment
seawall
top elevation
determination