期刊文献+

多通道信号隔离的高精度数据采集系统 被引量:7

Smart Data Acquisition System with Multi-Channel Signals Isolated
下载PDF
导出
摘要 普通检测设备在进行多个检测点同时采集数据时,由于多路采集信号参考点不同而相互干扰。采用悬浮电路将多路通道信号隔离,实现了各路激励电源和采集信号分别进行转换,有效地抑制了干扰成份。特别是在运用护环法检测技术进行钢筋混凝土腐蚀的检测系统中,取得了较好的效果。 Simple detecting device is' not authentic enough for the output signals' reference points are different. This system isolates signals with suspending circuits. Different prompting powers and signals are converted separately and disturber is resisted. It can obtain more authentic data in steel bar corrosion detecting of reinforced concrete when using guard ring detecting technology. Primary acquisition results show that this technique improves veracity and accuracy distinctly.
出处 《微计算机信息》 北大核心 2008年第28期157-159,156,共4页 Control & Automation
基金 国家自然科学基金项目"混凝土中带锈钢筋表面状态对其后期腐蚀规律的影响"(50371011)
关键词 钢筋混凝土 腐蚀 检测 隔离 数据采集 Reinforced concrete Corrosion Detecting Isolation Data acquisition
  • 相关文献

参考文献2

二级参考文献15

  • 1王彦芳,王小平,刘永军,雷宇.高速串行通信接口电路的CPLD实现[J].微计算机信息,2006(05Z):197-199. 被引量:6
  • 2Montemor M F,Simoes A M P,Ferreira M G S.Chloride-induced corrosion on reinforcing steel:from the fundamentals to the monitoring techniques[J].Cement and Concrete Composites,2003,25 (4-5 SPEC):491-502
  • 3Feliu S,Gonzalez J A.Determining polarization resistance in reinforced concrete slabs[J].Corros.Sci,1989,29(1):105-113
  • 4Law D W,Millard S G,Bungey J H.Linear polarization resistance measurements using a potentiostatically controlled guard ring[J].NDT and E International,2000,33 (1):15-21
  • 5Sehgal A L D,Kho Y T,Osseo-Asare K,et al.Reproducibility of polarization resistance measurements in steel-in-concrete systems[J].Corrosion,1992,48(9):706-714
  • 6Wojtas H.Determination of polarization resistance of reinforcement with a sensorized guard ring:analysis of errors[J].Corrosion,2004,60(4):414-420
  • 7Stern M,Geary A L.Electrochemical polarization I.A theoretical analysis of the shape of polarization curves[J].J.Electrochem.Soc,1957,104(1):56-63
  • 8Alonso C,Andrade A,Gonzalez J A.Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types[J].Cement Concrete Res,1988,8:687-698
  • 9Feliu S,Gonzalez J A,Andrade C.Effect of current distribution on corrosion rate measurements in reinforced concrete[J].Corrosion (Houston),1995,51(1):79-86
  • 10Wojtas H.Determination of corrosion rate of reinforcement with a modulated guard ring electrode:analysis of errors due to lateral current distribution[J].Corros.Sci,2004,46(7):1621-1632