磁共振设备安装调试过程中的不常见故障与对策 被引量:3

Unfamiliar Artifacts and Elimination of MRI Installation and Adjustment
下载PDF
导出
摘要 目的:探讨磁共振设备安装调试过程中几种不常见伪影的成因与消除方法。方法:回顾性分析了近三年来i_Open 0.36T磁共振设备安装调试过程中遇到的困难问题和不常见伪影,分析其图象表现和干扰来源,给出了改善方案。结果:干扰来源:外部(屏蔽门没有关严导致外界射频干扰进入磁体空间);屏蔽室内照明灯、激光定位灯;射频、梯度线圈(发热后绝缘材料性能降低后的瞬时放电);冷却系统部件(特别是水管接头);信号采集的模拟电路(放大器、连线、滤波板);信号采集后的数字电路(ADC等,不可测因素较少)。结论:本文列举故障的排除虽简单,但寻找故障的原因可能耗费大量的时间。在此整理分析,供广大同仁参考。以期在磁共振设备的安装调试时,提高效率,保证质量,更好为医院和患者服务。 Objective: 5 examples of unfamiliar artifacts of 0.36T MRI at past 3 years presented, and the reason and solution were analysed. Result: The result shows that the main interference is from:a. External (not related to strict platform screen doors lead outside RF interference into the magnet space);b, indoor lights, laser positioning lights; RF and gradient coils (heat insulation material properties decreased after the instantaneous discharge);c. Cooling system components (especially water mains connector); signal acquisition of analog circuits (amplifiers, connect ware, filter plate);d. Digital Circuit (ADC, imponderables less). Conclusion: We expect the work is benefit to magnetic resonance practitioners.
出处 《中国医学物理学杂志》 CSCD 2008年第5期838-840,共3页 Chinese Journal of Medical Physics
基金 泰山医学院青年基金项目(批准号:092)
关键词 磁共振成像 安装调试 不常见伪影 质量保证 magnetic resonance imaging installation and adjustment unfamiliar artifacts quality control
  • 相关文献

参考文献5

二级参考文献33

  • 1侯正松,江贵平,王华峰,陈武凡.MR图像刚性平移运动伪影的自动逆向迭代修正[J].中国生物医学工程学报,2004,23(4):353-358. 被引量:9
  • 2Buonocore MH,Gao L.Ghost artifact reduction for each planar imaging using image phase correction.Magn Reson Med,1997;38:89
  • 3Franciszek H.Image-based reduction of artifacts in multishot echo-planar imaging.Journal of Magnetic Resonance,1 998;134;206
  • 4Buonocore MH,David CZ.High spatial resolution EPI using an odd number of interleaves.Magnetic Resonance in Medieine,1999;41:1199
  • 5Hu X and Le TH.Artifact reduction in EPI with phaseencoded reference.Magn Reson Med,1996;36:166
  • 6Peter K,Elliot RMV.Ghost artifact cancellation using phased array processing.Magnetic Resonance in Medicine,2001;46:335
  • 7Wang JJ,Lin L,Anne C,et al.Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 tesla.Magnetic Resonance Imaging,2004;22(1):1
  • 8Garreffa G,Carnì M,Gualniera G,el al.Real-time MR artifacts filtering during continuous EEG/fMRI acquisition.Magnetie Resonance Imaging,2003;21(10):1175
  • 9Christian W,Herhert L,Thomas S,et al.On the origin of respiratory artifacts in BOLD-EPI of the human brain.Magnetic Resonance Imaging,2002;20(8):575
  • 10Markus K,Markus B,Ewald M.Comparison of multi-echo spiral and echo planar imaging in functional MRI.Magnetic Resonance Imaging,2002;20(4):359

共引文献9

同被引文献38

引证文献3

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部